    Little is known if there are similarities in vertebral trabecular bones of goat and human spine. This study is to verify if goat spine can be used for research at the bone tissue level. We extracted goat vertebral traebcular bone cubes and located trabecular rods that span the entire cube's length using microCT imaging to facilitate ultrasonic testing. An average acoustic velocity of 3112 m/s was obtained and correlated tissue modulus to hounsfield number. Average correlation was strong at 0.7661 in all directions and tissue modulus did not exhibit directionality. Compared to human, the modulus obtain from this study were within range. This suggests that it is the microarchitecture of trabecular bone that attributes to its anisotropy and variations in apparent modulus at different anatomical location and species.

    Original languageEnglish (US)
    Title of host publicationProceedings of the Second IASTED International Conference on Biomechanics
    EditorsM.H. Hamza
    Pages55-59
    Number of pages5
    StatePublished - Dec 1 2004
    EventProceedings of the Second IASTED International Conference on Biomechanics - Honolulu, HI, United States
    Duration: Aug 23 2004Aug 25 2004

    Other

    OtherProceedings of the Second IASTED International Conference on Biomechanics
    CountryUnited States
    CityHonolulu, HI
    Period8/23/048/25/04

    Fingerprint

    Bone
    Ultrasonics
    Tissue
    Ultrasonic testing
    Acoustic wave velocity
    Anisotropy
    Imaging techniques

    Keywords

    • Animal Model
    • MicroCT
    • Spine
    • Trabecular Bone
    • Ultrasonic Testing

    ASJC Scopus subject areas

    • Engineering(all)

    Cite this

    Teo, J., Png, A. Z. C., & Teoh, S. H. (2004). Vertebral trabecular tissue modulus of goat as compared to human using ultrasonic and microct approach. In M. H. Hamza (Ed.), Proceedings of the Second IASTED International Conference on Biomechanics (pp. 55-59). [463-031]

    Vertebral trabecular tissue modulus of goat as compared to human using ultrasonic and microct approach. / Teo, Jeremy; Png, Andy Z C; Teoh, Swee Hin.

    Proceedings of the Second IASTED International Conference on Biomechanics. ed. / M.H. Hamza. 2004. p. 55-59 463-031.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Teo, J, Png, AZC & Teoh, SH 2004, Vertebral trabecular tissue modulus of goat as compared to human using ultrasonic and microct approach. in MH Hamza (ed.), Proceedings of the Second IASTED International Conference on Biomechanics., 463-031, pp. 55-59, Proceedings of the Second IASTED International Conference on Biomechanics, Honolulu, HI, United States, 8/23/04.
    Teo J, Png AZC, Teoh SH. Vertebral trabecular tissue modulus of goat as compared to human using ultrasonic and microct approach. In Hamza MH, editor, Proceedings of the Second IASTED International Conference on Biomechanics. 2004. p. 55-59. 463-031
    Teo, Jeremy ; Png, Andy Z C ; Teoh, Swee Hin. / Vertebral trabecular tissue modulus of goat as compared to human using ultrasonic and microct approach. Proceedings of the Second IASTED International Conference on Biomechanics. editor / M.H. Hamza. 2004. pp. 55-59
    @inproceedings{79f9cdf3b8de4d21810aa361635bd884,
    title = "Vertebral trabecular tissue modulus of goat as compared to human using ultrasonic and microct approach",
    abstract = "Little is known if there are similarities in vertebral trabecular bones of goat and human spine. This study is to verify if goat spine can be used for research at the bone tissue level. We extracted goat vertebral traebcular bone cubes and located trabecular rods that span the entire cube's length using microCT imaging to facilitate ultrasonic testing. An average acoustic velocity of 3112 m/s was obtained and correlated tissue modulus to hounsfield number. Average correlation was strong at 0.7661 in all directions and tissue modulus did not exhibit directionality. Compared to human, the modulus obtain from this study were within range. This suggests that it is the microarchitecture of trabecular bone that attributes to its anisotropy and variations in apparent modulus at different anatomical location and species.",
    keywords = "Animal Model, MicroCT, Spine, Trabecular Bone, Ultrasonic Testing",
    author = "Jeremy Teo and Png, {Andy Z C} and Teoh, {Swee Hin}",
    year = "2004",
    month = "12",
    day = "1",
    language = "English (US)",
    isbn = "0889864489",
    pages = "55--59",
    editor = "M.H. Hamza",
    booktitle = "Proceedings of the Second IASTED International Conference on Biomechanics",

    }

    TY - GEN

    T1 - Vertebral trabecular tissue modulus of goat as compared to human using ultrasonic and microct approach

    AU - Teo, Jeremy

    AU - Png, Andy Z C

    AU - Teoh, Swee Hin

    PY - 2004/12/1

    Y1 - 2004/12/1

    N2 - Little is known if there are similarities in vertebral trabecular bones of goat and human spine. This study is to verify if goat spine can be used for research at the bone tissue level. We extracted goat vertebral traebcular bone cubes and located trabecular rods that span the entire cube's length using microCT imaging to facilitate ultrasonic testing. An average acoustic velocity of 3112 m/s was obtained and correlated tissue modulus to hounsfield number. Average correlation was strong at 0.7661 in all directions and tissue modulus did not exhibit directionality. Compared to human, the modulus obtain from this study were within range. This suggests that it is the microarchitecture of trabecular bone that attributes to its anisotropy and variations in apparent modulus at different anatomical location and species.

    AB - Little is known if there are similarities in vertebral trabecular bones of goat and human spine. This study is to verify if goat spine can be used for research at the bone tissue level. We extracted goat vertebral traebcular bone cubes and located trabecular rods that span the entire cube's length using microCT imaging to facilitate ultrasonic testing. An average acoustic velocity of 3112 m/s was obtained and correlated tissue modulus to hounsfield number. Average correlation was strong at 0.7661 in all directions and tissue modulus did not exhibit directionality. Compared to human, the modulus obtain from this study were within range. This suggests that it is the microarchitecture of trabecular bone that attributes to its anisotropy and variations in apparent modulus at different anatomical location and species.

    KW - Animal Model

    KW - MicroCT

    KW - Spine

    KW - Trabecular Bone

    KW - Ultrasonic Testing

    UR - http://www.scopus.com/inward/record.url?scp=11144256315&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=11144256315&partnerID=8YFLogxK

    M3 - Conference contribution

    SN - 0889864489

    SN - 9780889864481

    SP - 55

    EP - 59

    BT - Proceedings of the Second IASTED International Conference on Biomechanics

    A2 - Hamza, M.H.

    ER -