The effect of osteotomy dimension on osseointegration to resorbable media-treated implants: A study in the sheep

Silvia Galli, Ryo Jimbo, Nick Tovar, Daniel Y. Yoo, Rodolfo B. Anchieta, Satoshi Yamaguchi, Paulo Coelho

Research output: Contribution to journalArticle

Abstract

The drilling technique and the surface characteristics are known to influence the healing times of oral implants. The influence of osteotomy dimension on osseointegration of microroughned implant surfaces treated with resorbable blasting media was tested in an in vivo model.Ninety-six implants (ø4.5 mm, 8 mm in length) with resorbable blasting media-treated surfaces were placed in the ileum of six sheep. The final osteotomy diameters were 4.6 mm (reamer), 4.1 mm (loose), 3.7 mm (medium), and 3.2 mm (tight). After three and six weeks of healing, the implants were biomechanically tested and histologically evaluated. Statistical analysis was performed using Page L trend test for ordered and paired sample and linear regression, with significance level at p < 0.05.An overall increase in all dependent variables was observed with the reduction of osteotomy diameter. In addition, all osseointegration scores increased over time. At three weeks, the retention was significantly higher for smaller osteotomies. The histological sections depicted intimate contact of bone with all the implant surfaces and osteoblast lines were visible in all sections.The resorbable blasting media microroughed surfaces achieved successful osseointegration for all the instrumentation procedures tested, with higher osseointegration scores for the high insertion torque group.

Original languageEnglish (US)
Pages (from-to)1068-1074
Number of pages7
JournalJournal of Biomaterials Applications
Volume29
Issue number8
DOIs
StatePublished - Mar 26 2015

Fingerprint

Blasting
Reamers
Osteoblasts
Linear regression
Drilling
Statistical methods
Bone
Torque

Keywords

  • histology
  • Implant surface
  • osseointegration
  • removal torque
  • resorbable surface - blasted surface

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials

Cite this

The effect of osteotomy dimension on osseointegration to resorbable media-treated implants : A study in the sheep. / Galli, Silvia; Jimbo, Ryo; Tovar, Nick; Yoo, Daniel Y.; Anchieta, Rodolfo B.; Yamaguchi, Satoshi; Coelho, Paulo.

In: Journal of Biomaterials Applications, Vol. 29, No. 8, 26.03.2015, p. 1068-1074.

Research output: Contribution to journalArticle

Galli, Silvia ; Jimbo, Ryo ; Tovar, Nick ; Yoo, Daniel Y. ; Anchieta, Rodolfo B. ; Yamaguchi, Satoshi ; Coelho, Paulo. / The effect of osteotomy dimension on osseointegration to resorbable media-treated implants : A study in the sheep. In: Journal of Biomaterials Applications. 2015 ; Vol. 29, No. 8. pp. 1068-1074.
@article{7a82117e3b4f4ef38fc087d0e8764b18,
title = "The effect of osteotomy dimension on osseointegration to resorbable media-treated implants: A study in the sheep",
abstract = "The drilling technique and the surface characteristics are known to influence the healing times of oral implants. The influence of osteotomy dimension on osseointegration of microroughned implant surfaces treated with resorbable blasting media was tested in an in vivo model.Ninety-six implants ({\o}4.5 mm, 8 mm in length) with resorbable blasting media-treated surfaces were placed in the ileum of six sheep. The final osteotomy diameters were 4.6 mm (reamer), 4.1 mm (loose), 3.7 mm (medium), and 3.2 mm (tight). After three and six weeks of healing, the implants were biomechanically tested and histologically evaluated. Statistical analysis was performed using Page L trend test for ordered and paired sample and linear regression, with significance level at p < 0.05.An overall increase in all dependent variables was observed with the reduction of osteotomy diameter. In addition, all osseointegration scores increased over time. At three weeks, the retention was significantly higher for smaller osteotomies. The histological sections depicted intimate contact of bone with all the implant surfaces and osteoblast lines were visible in all sections.The resorbable blasting media microroughed surfaces achieved successful osseointegration for all the instrumentation procedures tested, with higher osseointegration scores for the high insertion torque group.",
keywords = "histology, Implant surface, osseointegration, removal torque, resorbable surface - blasted surface",
author = "Silvia Galli and Ryo Jimbo and Nick Tovar and Yoo, {Daniel Y.} and Anchieta, {Rodolfo B.} and Satoshi Yamaguchi and Paulo Coelho",
year = "2015",
month = "3",
day = "26",
doi = "10.1177/0885328214553958",
language = "English (US)",
volume = "29",
pages = "1068--1074",
journal = "Journal of Biomaterials Applications",
issn = "0885-3282",
publisher = "SAGE Publications Ltd",
number = "8",

}

TY - JOUR

T1 - The effect of osteotomy dimension on osseointegration to resorbable media-treated implants

T2 - A study in the sheep

AU - Galli, Silvia

AU - Jimbo, Ryo

AU - Tovar, Nick

AU - Yoo, Daniel Y.

AU - Anchieta, Rodolfo B.

AU - Yamaguchi, Satoshi

AU - Coelho, Paulo

PY - 2015/3/26

Y1 - 2015/3/26

N2 - The drilling technique and the surface characteristics are known to influence the healing times of oral implants. The influence of osteotomy dimension on osseointegration of microroughned implant surfaces treated with resorbable blasting media was tested in an in vivo model.Ninety-six implants (ø4.5 mm, 8 mm in length) with resorbable blasting media-treated surfaces were placed in the ileum of six sheep. The final osteotomy diameters were 4.6 mm (reamer), 4.1 mm (loose), 3.7 mm (medium), and 3.2 mm (tight). After three and six weeks of healing, the implants were biomechanically tested and histologically evaluated. Statistical analysis was performed using Page L trend test for ordered and paired sample and linear regression, with significance level at p < 0.05.An overall increase in all dependent variables was observed with the reduction of osteotomy diameter. In addition, all osseointegration scores increased over time. At three weeks, the retention was significantly higher for smaller osteotomies. The histological sections depicted intimate contact of bone with all the implant surfaces and osteoblast lines were visible in all sections.The resorbable blasting media microroughed surfaces achieved successful osseointegration for all the instrumentation procedures tested, with higher osseointegration scores for the high insertion torque group.

AB - The drilling technique and the surface characteristics are known to influence the healing times of oral implants. The influence of osteotomy dimension on osseointegration of microroughned implant surfaces treated with resorbable blasting media was tested in an in vivo model.Ninety-six implants (ø4.5 mm, 8 mm in length) with resorbable blasting media-treated surfaces were placed in the ileum of six sheep. The final osteotomy diameters were 4.6 mm (reamer), 4.1 mm (loose), 3.7 mm (medium), and 3.2 mm (tight). After three and six weeks of healing, the implants were biomechanically tested and histologically evaluated. Statistical analysis was performed using Page L trend test for ordered and paired sample and linear regression, with significance level at p < 0.05.An overall increase in all dependent variables was observed with the reduction of osteotomy diameter. In addition, all osseointegration scores increased over time. At three weeks, the retention was significantly higher for smaller osteotomies. The histological sections depicted intimate contact of bone with all the implant surfaces and osteoblast lines were visible in all sections.The resorbable blasting media microroughed surfaces achieved successful osseointegration for all the instrumentation procedures tested, with higher osseointegration scores for the high insertion torque group.

KW - histology

KW - Implant surface

KW - osseointegration

KW - removal torque

KW - resorbable surface - blasted surface

UR - http://www.scopus.com/inward/record.url?scp=84923358705&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84923358705&partnerID=8YFLogxK

U2 - 10.1177/0885328214553958

DO - 10.1177/0885328214553958

M3 - Article

C2 - 25281647

AN - SCOPUS:84923358705

VL - 29

SP - 1068

EP - 1074

JO - Journal of Biomaterials Applications

JF - Journal of Biomaterials Applications

SN - 0885-3282

IS - 8

ER -