Selection of copper against aluminium windings for distribution transformers

J. C. Olivares-Galván, Francisco De Leon, P. S. Georgilakis, R. Escarela-Pérez

Research output: Contribution to journalArticle

Abstract

Copper and aluminium are the two conductors most commonly used in transformer windings. This study presents a comprehensive comparison of distribution transformers built either with copper or with aluminium windings. The comparison is based on winding material conductivity, density, cost, connectivity, oxidation, machinability and behaviour under short-circuit. Additionally, a parametric analysis of transformer designs as a function of the cost of copper against aluminium is presented. The study establishes the winding material cost range that indicates when it is more economical to build the transformer windings with copper or with aluminium. All comparisons are carried out with cost of optimised transformer designs that fulfil all specifications together with manufacturing and operating constraints.

Original languageEnglish (US)
Article numberIEPAAN000004000006000474000001
Pages (from-to)474-485
Number of pages12
JournalIET Electric Power Applications
Volume4
Issue number6
DOIs
StatePublished - Jul 2010

Fingerprint

Copper
Aluminum
Transformer windings
Costs
Machinability
Short circuit currents
Specifications
Oxidation

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Olivares-Galván, J. C., De Leon, F., Georgilakis, P. S., & Escarela-Pérez, R. (2010). Selection of copper against aluminium windings for distribution transformers. IET Electric Power Applications, 4(6), 474-485. [IEPAAN000004000006000474000001]. https://doi.org/10.1049/iet-epa.2009.0297

Selection of copper against aluminium windings for distribution transformers. / Olivares-Galván, J. C.; De Leon, Francisco; Georgilakis, P. S.; Escarela-Pérez, R.

In: IET Electric Power Applications, Vol. 4, No. 6, IEPAAN000004000006000474000001, 07.2010, p. 474-485.

Research output: Contribution to journalArticle

Olivares-Galván, JC, De Leon, F, Georgilakis, PS & Escarela-Pérez, R 2010, 'Selection of copper against aluminium windings for distribution transformers', IET Electric Power Applications, vol. 4, no. 6, IEPAAN000004000006000474000001, pp. 474-485. https://doi.org/10.1049/iet-epa.2009.0297
Olivares-Galván JC, De Leon F, Georgilakis PS, Escarela-Pérez R. Selection of copper against aluminium windings for distribution transformers. IET Electric Power Applications. 2010 Jul;4(6):474-485. IEPAAN000004000006000474000001. https://doi.org/10.1049/iet-epa.2009.0297
Olivares-Galván, J. C. ; De Leon, Francisco ; Georgilakis, P. S. ; Escarela-Pérez, R. / Selection of copper against aluminium windings for distribution transformers. In: IET Electric Power Applications. 2010 ; Vol. 4, No. 6. pp. 474-485.
@article{2efff3b6cafc4bc283fcd41764bb8be3,
title = "Selection of copper against aluminium windings for distribution transformers",
abstract = "Copper and aluminium are the two conductors most commonly used in transformer windings. This study presents a comprehensive comparison of distribution transformers built either with copper or with aluminium windings. The comparison is based on winding material conductivity, density, cost, connectivity, oxidation, machinability and behaviour under short-circuit. Additionally, a parametric analysis of transformer designs as a function of the cost of copper against aluminium is presented. The study establishes the winding material cost range that indicates when it is more economical to build the transformer windings with copper or with aluminium. All comparisons are carried out with cost of optimised transformer designs that fulfil all specifications together with manufacturing and operating constraints.",
author = "Olivares-Galv{\'a}n, {J. C.} and {De Leon}, Francisco and Georgilakis, {P. S.} and R. Escarela-P{\'e}rez",
year = "2010",
month = "7",
doi = "10.1049/iet-epa.2009.0297",
language = "English (US)",
volume = "4",
pages = "474--485",
journal = "IET Electric Power Applications",
issn = "1751-8660",
publisher = "Institution of Engineering and Technology",
number = "6",

}

TY - JOUR

T1 - Selection of copper against aluminium windings for distribution transformers

AU - Olivares-Galván, J. C.

AU - De Leon, Francisco

AU - Georgilakis, P. S.

AU - Escarela-Pérez, R.

PY - 2010/7

Y1 - 2010/7

N2 - Copper and aluminium are the two conductors most commonly used in transformer windings. This study presents a comprehensive comparison of distribution transformers built either with copper or with aluminium windings. The comparison is based on winding material conductivity, density, cost, connectivity, oxidation, machinability and behaviour under short-circuit. Additionally, a parametric analysis of transformer designs as a function of the cost of copper against aluminium is presented. The study establishes the winding material cost range that indicates when it is more economical to build the transformer windings with copper or with aluminium. All comparisons are carried out with cost of optimised transformer designs that fulfil all specifications together with manufacturing and operating constraints.

AB - Copper and aluminium are the two conductors most commonly used in transformer windings. This study presents a comprehensive comparison of distribution transformers built either with copper or with aluminium windings. The comparison is based on winding material conductivity, density, cost, connectivity, oxidation, machinability and behaviour under short-circuit. Additionally, a parametric analysis of transformer designs as a function of the cost of copper against aluminium is presented. The study establishes the winding material cost range that indicates when it is more economical to build the transformer windings with copper or with aluminium. All comparisons are carried out with cost of optimised transformer designs that fulfil all specifications together with manufacturing and operating constraints.

UR - http://www.scopus.com/inward/record.url?scp=77956562380&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77956562380&partnerID=8YFLogxK

U2 - 10.1049/iet-epa.2009.0297

DO - 10.1049/iet-epa.2009.0297

M3 - Article

AN - SCOPUS:77956562380

VL - 4

SP - 474

EP - 485

JO - IET Electric Power Applications

JF - IET Electric Power Applications

SN - 1751-8660

IS - 6

M1 - IEPAAN000004000006000474000001

ER -