Revisiting the role of implant design and surgical instrumentation on osseointegration

Paulo Coelho, Estevam A. Bonfante, Ryo Jimbo

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Osseointegration of metallic devices has shown to be successful in several biomedical fields. Despite the high success rates, continuous efforts to reduce osseointegration time have been marked by investigations considering a limited number of variables. Recent research has pointed that the interplay between surgical instrumentation and device macrogeometry not only plays a key role on both early and delayed stages of osseointegration but may also be key in how efficient smaller length scale designing (at the micro- and nanogeometrical levels) may be in hastening early stages of osseointegration. The present chapter focuses on how the different metallic device design length scales' interplay (macro, micro, and nano) affects the bone response and how its understanding may affect the next generation of metallic device designing for osseointegration.

Original languageEnglish (US)
Title of host publicationImplant Aesthetics
Subtitle of host publicationKeys to Diagnosis and Treatment
PublisherSpringer International Publishing
Pages43-56
Number of pages14
ISBN (Electronic)9783319507064
ISBN (Print)9783319507040
DOIs
StatePublished - Jun 16 2017

Fingerprint

Osseointegration
Equipment and Supplies
Equipment Design
Bone and Bones
Research

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Coelho, P., Bonfante, E. A., & Jimbo, R. (2017). Revisiting the role of implant design and surgical instrumentation on osseointegration. In Implant Aesthetics: Keys to Diagnosis and Treatment (pp. 43-56). Springer International Publishing. https://doi.org/10.1007/978-3-319-50706-4_4

Revisiting the role of implant design and surgical instrumentation on osseointegration. / Coelho, Paulo; Bonfante, Estevam A.; Jimbo, Ryo.

Implant Aesthetics: Keys to Diagnosis and Treatment. Springer International Publishing, 2017. p. 43-56.

Research output: Chapter in Book/Report/Conference proceedingChapter

Coelho, P, Bonfante, EA & Jimbo, R 2017, Revisiting the role of implant design and surgical instrumentation on osseointegration. in Implant Aesthetics: Keys to Diagnosis and Treatment. Springer International Publishing, pp. 43-56. https://doi.org/10.1007/978-3-319-50706-4_4
Coelho P, Bonfante EA, Jimbo R. Revisiting the role of implant design and surgical instrumentation on osseointegration. In Implant Aesthetics: Keys to Diagnosis and Treatment. Springer International Publishing. 2017. p. 43-56 https://doi.org/10.1007/978-3-319-50706-4_4
Coelho, Paulo ; Bonfante, Estevam A. ; Jimbo, Ryo. / Revisiting the role of implant design and surgical instrumentation on osseointegration. Implant Aesthetics: Keys to Diagnosis and Treatment. Springer International Publishing, 2017. pp. 43-56
@inbook{29f72e8b37754abca7f0af2120549abd,
title = "Revisiting the role of implant design and surgical instrumentation on osseointegration",
abstract = "Osseointegration of metallic devices has shown to be successful in several biomedical fields. Despite the high success rates, continuous efforts to reduce osseointegration time have been marked by investigations considering a limited number of variables. Recent research has pointed that the interplay between surgical instrumentation and device macrogeometry not only plays a key role on both early and delayed stages of osseointegration but may also be key in how efficient smaller length scale designing (at the micro- and nanogeometrical levels) may be in hastening early stages of osseointegration. The present chapter focuses on how the different metallic device design length scales' interplay (macro, micro, and nano) affects the bone response and how its understanding may affect the next generation of metallic device designing for osseointegration.",
author = "Paulo Coelho and Bonfante, {Estevam A.} and Ryo Jimbo",
year = "2017",
month = "6",
day = "16",
doi = "10.1007/978-3-319-50706-4_4",
language = "English (US)",
isbn = "9783319507040",
pages = "43--56",
booktitle = "Implant Aesthetics",
publisher = "Springer International Publishing",

}

TY - CHAP

T1 - Revisiting the role of implant design and surgical instrumentation on osseointegration

AU - Coelho, Paulo

AU - Bonfante, Estevam A.

AU - Jimbo, Ryo

PY - 2017/6/16

Y1 - 2017/6/16

N2 - Osseointegration of metallic devices has shown to be successful in several biomedical fields. Despite the high success rates, continuous efforts to reduce osseointegration time have been marked by investigations considering a limited number of variables. Recent research has pointed that the interplay between surgical instrumentation and device macrogeometry not only plays a key role on both early and delayed stages of osseointegration but may also be key in how efficient smaller length scale designing (at the micro- and nanogeometrical levels) may be in hastening early stages of osseointegration. The present chapter focuses on how the different metallic device design length scales' interplay (macro, micro, and nano) affects the bone response and how its understanding may affect the next generation of metallic device designing for osseointegration.

AB - Osseointegration of metallic devices has shown to be successful in several biomedical fields. Despite the high success rates, continuous efforts to reduce osseointegration time have been marked by investigations considering a limited number of variables. Recent research has pointed that the interplay between surgical instrumentation and device macrogeometry not only plays a key role on both early and delayed stages of osseointegration but may also be key in how efficient smaller length scale designing (at the micro- and nanogeometrical levels) may be in hastening early stages of osseointegration. The present chapter focuses on how the different metallic device design length scales' interplay (macro, micro, and nano) affects the bone response and how its understanding may affect the next generation of metallic device designing for osseointegration.

UR - http://www.scopus.com/inward/record.url?scp=85055153940&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85055153940&partnerID=8YFLogxK

U2 - 10.1007/978-3-319-50706-4_4

DO - 10.1007/978-3-319-50706-4_4

M3 - Chapter

AN - SCOPUS:85055153940

SN - 9783319507040

SP - 43

EP - 56

BT - Implant Aesthetics

PB - Springer International Publishing

ER -