Radial mass sensitivity of the quartz crystal microbalance in liquid media

Michael Ward, Edward J. Delawski

Research output: Contribution to journalArticle

Abstract

The radial sensitivity function of the quartz crystal microbalance (QCM), employing an AT-cut quartz resonator In aqueous media, has been determined by simultaneous in situ measurement of frequency and charge during copper electrodeposition in holes etched In a photoresist polymer on the QCM. Frequency-charge correlations are determined by copper deposition either in small (0.025 in.) holes with different angular and radial locations or in concentric circular holes with different radil. The data indicate a Gaussian mass sensitivity distribution, with the greatest differential sensitivity in the center of the resonator, decreasing monotonically with Increasing radius. Narrower sensitivity distributions and less mass sensitivity beyond the electrode edges were observed wtth plano-convex crystals, consistent with a greater degree of energy trapping that results from the larger mass in the center of contoured crystals. The results demonstrate, as with applications of the QCM in the gas phase, that coating uniformity is important for accurate measurements of mass with the QCM when used in liquid media. The significant sensitivity observed beyond the electrode boundary in plano-plano resonators indicates that sensors for liquid-phase applications must be properly calibrated to account for this property.

Original languageEnglish (US)
Pages (from-to)886-890
Number of pages5
JournalAnalytical Chemistry
Volume63
Issue number9
StatePublished - May 1 1991

Fingerprint

Quartz crystal microbalances
Resonators
Liquids
Copper
Crystals
Electrodes
Quartz
Photoresists
Electrodeposition
Polymers
Gases
Coatings
Sensors

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Radial mass sensitivity of the quartz crystal microbalance in liquid media. / Ward, Michael; Delawski, Edward J.

In: Analytical Chemistry, Vol. 63, No. 9, 01.05.1991, p. 886-890.

Research output: Contribution to journalArticle

@article{cc392c06ed1840f28709dbbcd8e21cd0,
title = "Radial mass sensitivity of the quartz crystal microbalance in liquid media",
abstract = "The radial sensitivity function of the quartz crystal microbalance (QCM), employing an AT-cut quartz resonator In aqueous media, has been determined by simultaneous in situ measurement of frequency and charge during copper electrodeposition in holes etched In a photoresist polymer on the QCM. Frequency-charge correlations are determined by copper deposition either in small (0.025 in.) holes with different angular and radial locations or in concentric circular holes with different radil. The data indicate a Gaussian mass sensitivity distribution, with the greatest differential sensitivity in the center of the resonator, decreasing monotonically with Increasing radius. Narrower sensitivity distributions and less mass sensitivity beyond the electrode edges were observed wtth plano-convex crystals, consistent with a greater degree of energy trapping that results from the larger mass in the center of contoured crystals. The results demonstrate, as with applications of the QCM in the gas phase, that coating uniformity is important for accurate measurements of mass with the QCM when used in liquid media. The significant sensitivity observed beyond the electrode boundary in plano-plano resonators indicates that sensors for liquid-phase applications must be properly calibrated to account for this property.",
author = "Michael Ward and Delawski, {Edward J.}",
year = "1991",
month = "5",
day = "1",
language = "English (US)",
volume = "63",
pages = "886--890",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "9",

}

TY - JOUR

T1 - Radial mass sensitivity of the quartz crystal microbalance in liquid media

AU - Ward, Michael

AU - Delawski, Edward J.

PY - 1991/5/1

Y1 - 1991/5/1

N2 - The radial sensitivity function of the quartz crystal microbalance (QCM), employing an AT-cut quartz resonator In aqueous media, has been determined by simultaneous in situ measurement of frequency and charge during copper electrodeposition in holes etched In a photoresist polymer on the QCM. Frequency-charge correlations are determined by copper deposition either in small (0.025 in.) holes with different angular and radial locations or in concentric circular holes with different radil. The data indicate a Gaussian mass sensitivity distribution, with the greatest differential sensitivity in the center of the resonator, decreasing monotonically with Increasing radius. Narrower sensitivity distributions and less mass sensitivity beyond the electrode edges were observed wtth plano-convex crystals, consistent with a greater degree of energy trapping that results from the larger mass in the center of contoured crystals. The results demonstrate, as with applications of the QCM in the gas phase, that coating uniformity is important for accurate measurements of mass with the QCM when used in liquid media. The significant sensitivity observed beyond the electrode boundary in plano-plano resonators indicates that sensors for liquid-phase applications must be properly calibrated to account for this property.

AB - The radial sensitivity function of the quartz crystal microbalance (QCM), employing an AT-cut quartz resonator In aqueous media, has been determined by simultaneous in situ measurement of frequency and charge during copper electrodeposition in holes etched In a photoresist polymer on the QCM. Frequency-charge correlations are determined by copper deposition either in small (0.025 in.) holes with different angular and radial locations or in concentric circular holes with different radil. The data indicate a Gaussian mass sensitivity distribution, with the greatest differential sensitivity in the center of the resonator, decreasing monotonically with Increasing radius. Narrower sensitivity distributions and less mass sensitivity beyond the electrode edges were observed wtth plano-convex crystals, consistent with a greater degree of energy trapping that results from the larger mass in the center of contoured crystals. The results demonstrate, as with applications of the QCM in the gas phase, that coating uniformity is important for accurate measurements of mass with the QCM when used in liquid media. The significant sensitivity observed beyond the electrode boundary in plano-plano resonators indicates that sensors for liquid-phase applications must be properly calibrated to account for this property.

UR - http://www.scopus.com/inward/record.url?scp=0000847853&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0000847853&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0000847853

VL - 63

SP - 886

EP - 890

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 9

ER -