Quantitative sensory nerve conduction threshold (sNCT) evaluation of the trigeminal nerve at the mental foramen area

Todd H. Lerner, Gary Goldstein, Eugene Hittelman

Research output: Contribution to journalArticle

Abstract

Statement of problem. There is a need for a quick, objective, quantitative sensory test of the mandibular inferior alveolar nerve to assess sensory dysfunction due to trauma, infection, or disease. Purpose. This study evaluated the reliability and reproducibility of a commercially available electrodiagnostic quantitative sensory nerve conduction threshold (sNCT) evaluation testing method and established normative values for future evaluation of nerve dysfunction. Material and methods. Rapid current perception threshold (R-CPT) values were obtained with Neurometer CPT/ C, an electrodiagnostic sNCT device that administers an alternating constant-current sinusoid waveform stimulus at either 2000 Hz (H) (Hertz [cycles/ second]), 250 Hz (M), or 5 Hz (L) at intensity levels ranging from 0.001 to 10 mA. Thirty-four healthy subjects were tested then retested by the same operator from 7 days to 153 days. R-CPT evaluation was performed over the mental foramen bilaterally with dual disposable gold-plated electrodes and a hypoallergenic electrode gel held in place using nonconductive adhesive tape. Two consecutive identical R-CPT measures were obtained for each stimulation frequency for determination of the final R-CPT value. Results. On the left side, there was no difference between the first and second test (P>.05). On the right side, there was a statistical difference between the first and second test for L, M, and H, but the confidence interval is very narrow and the differences are not clinically significant. Conclusion. From the values obtained, R-CPT testing was reliable for the quantification of sensory function in healthy individuals.

Original languageEnglish (US)
Pages (from-to)103-107
Number of pages5
JournalJournal of Prosthetic Dentistry
Volume84
Issue number1
DOIs
StatePublished - Jul 2000

Fingerprint

Trigeminal Nerve
Neural Conduction
Electrodes
Mandibular Nerve
Gold
Adhesives
Healthy Volunteers
Gels
Confidence Intervals
Equipment and Supplies
Wounds and Injuries
Infection

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Quantitative sensory nerve conduction threshold (sNCT) evaluation of the trigeminal nerve at the mental foramen area. / Lerner, Todd H.; Goldstein, Gary; Hittelman, Eugene.

In: Journal of Prosthetic Dentistry, Vol. 84, No. 1, 07.2000, p. 103-107.

Research output: Contribution to journalArticle

@article{ee980076ad4644e79c0d8e4046ee694e,
title = "Quantitative sensory nerve conduction threshold (sNCT) evaluation of the trigeminal nerve at the mental foramen area",
abstract = "Statement of problem. There is a need for a quick, objective, quantitative sensory test of the mandibular inferior alveolar nerve to assess sensory dysfunction due to trauma, infection, or disease. Purpose. This study evaluated the reliability and reproducibility of a commercially available electrodiagnostic quantitative sensory nerve conduction threshold (sNCT) evaluation testing method and established normative values for future evaluation of nerve dysfunction. Material and methods. Rapid current perception threshold (R-CPT) values were obtained with Neurometer CPT/ C, an electrodiagnostic sNCT device that administers an alternating constant-current sinusoid waveform stimulus at either 2000 Hz (H) (Hertz [cycles/ second]), 250 Hz (M), or 5 Hz (L) at intensity levels ranging from 0.001 to 10 mA. Thirty-four healthy subjects were tested then retested by the same operator from 7 days to 153 days. R-CPT evaluation was performed over the mental foramen bilaterally with dual disposable gold-plated electrodes and a hypoallergenic electrode gel held in place using nonconductive adhesive tape. Two consecutive identical R-CPT measures were obtained for each stimulation frequency for determination of the final R-CPT value. Results. On the left side, there was no difference between the first and second test (P>.05). On the right side, there was a statistical difference between the first and second test for L, M, and H, but the confidence interval is very narrow and the differences are not clinically significant. Conclusion. From the values obtained, R-CPT testing was reliable for the quantification of sensory function in healthy individuals.",
author = "Lerner, {Todd H.} and Gary Goldstein and Eugene Hittelman",
year = "2000",
month = "7",
doi = "10.1067/mpr.2000.107336",
language = "English (US)",
volume = "84",
pages = "103--107",
journal = "Journal of Prosthetic Dentistry",
issn = "0022-3913",
publisher = "Mosby Inc.",
number = "1",

}

TY - JOUR

T1 - Quantitative sensory nerve conduction threshold (sNCT) evaluation of the trigeminal nerve at the mental foramen area

AU - Lerner, Todd H.

AU - Goldstein, Gary

AU - Hittelman, Eugene

PY - 2000/7

Y1 - 2000/7

N2 - Statement of problem. There is a need for a quick, objective, quantitative sensory test of the mandibular inferior alveolar nerve to assess sensory dysfunction due to trauma, infection, or disease. Purpose. This study evaluated the reliability and reproducibility of a commercially available electrodiagnostic quantitative sensory nerve conduction threshold (sNCT) evaluation testing method and established normative values for future evaluation of nerve dysfunction. Material and methods. Rapid current perception threshold (R-CPT) values were obtained with Neurometer CPT/ C, an electrodiagnostic sNCT device that administers an alternating constant-current sinusoid waveform stimulus at either 2000 Hz (H) (Hertz [cycles/ second]), 250 Hz (M), or 5 Hz (L) at intensity levels ranging from 0.001 to 10 mA. Thirty-four healthy subjects were tested then retested by the same operator from 7 days to 153 days. R-CPT evaluation was performed over the mental foramen bilaterally with dual disposable gold-plated electrodes and a hypoallergenic electrode gel held in place using nonconductive adhesive tape. Two consecutive identical R-CPT measures were obtained for each stimulation frequency for determination of the final R-CPT value. Results. On the left side, there was no difference between the first and second test (P>.05). On the right side, there was a statistical difference between the first and second test for L, M, and H, but the confidence interval is very narrow and the differences are not clinically significant. Conclusion. From the values obtained, R-CPT testing was reliable for the quantification of sensory function in healthy individuals.

AB - Statement of problem. There is a need for a quick, objective, quantitative sensory test of the mandibular inferior alveolar nerve to assess sensory dysfunction due to trauma, infection, or disease. Purpose. This study evaluated the reliability and reproducibility of a commercially available electrodiagnostic quantitative sensory nerve conduction threshold (sNCT) evaluation testing method and established normative values for future evaluation of nerve dysfunction. Material and methods. Rapid current perception threshold (R-CPT) values were obtained with Neurometer CPT/ C, an electrodiagnostic sNCT device that administers an alternating constant-current sinusoid waveform stimulus at either 2000 Hz (H) (Hertz [cycles/ second]), 250 Hz (M), or 5 Hz (L) at intensity levels ranging from 0.001 to 10 mA. Thirty-four healthy subjects were tested then retested by the same operator from 7 days to 153 days. R-CPT evaluation was performed over the mental foramen bilaterally with dual disposable gold-plated electrodes and a hypoallergenic electrode gel held in place using nonconductive adhesive tape. Two consecutive identical R-CPT measures were obtained for each stimulation frequency for determination of the final R-CPT value. Results. On the left side, there was no difference between the first and second test (P>.05). On the right side, there was a statistical difference between the first and second test for L, M, and H, but the confidence interval is very narrow and the differences are not clinically significant. Conclusion. From the values obtained, R-CPT testing was reliable for the quantification of sensory function in healthy individuals.

UR - http://www.scopus.com/inward/record.url?scp=0034219355&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034219355&partnerID=8YFLogxK

U2 - 10.1067/mpr.2000.107336

DO - 10.1067/mpr.2000.107336

M3 - Article

VL - 84

SP - 103

EP - 107

JO - Journal of Prosthetic Dentistry

JF - Journal of Prosthetic Dentistry

SN - 0022-3913

IS - 1

ER -