PVDF-based microfabricated tactile sensor for minimally invasive surgery

Mohammad Qasaimeh, Saeed Sokhanvar, Javad Dargahi, Mojtaba Kahrizi

Research output: Contribution to journalArticle

Abstract

This paper aimed to develop a miniaturized tactile sensor capable of measuring force and force position in minimally invasive surgery. The in situ measurement of tactile information is a step forward toward restoring the loss of the sense of touch that has occurred due to shift from traditional to minimally invasive surgeries. The sensor was designed such that it can sense low forces which could be comparable to those produced by pulsating delicate arteries, yet can withstand high forces comparable to grasping forces. The influence of some hidden anatomical features, such as lumps, voids, and arteries, on the stress distribution at the grasping surface was studied. In this paper, the capability of the sensor to determine and locate any point load was also investigated. The proposed sensor was designed and manufactured to be highly sensitive, using polyvinylidene fluoride (PVDF). The microfabrication procedure of the sensor, including corner compensation for toothlike projections and patterning of PVDF film, was discussed. The micromachined sensor was tested, and the experimental results were compared with the results of 3-D finite element modeling.

Original languageEnglish (US)
Pages (from-to)195-207
Number of pages13
JournalJournal of Microelectromechanical Systems
Volume18
Issue number1
DOIs
StatePublished - Jan 1 2009

Fingerprint

Surgery
Sensors
Microfabrication
Stress concentration

Keywords

  • Microelectromechanical devices
  • Minimally invasive surgery (MIS)
  • Piezoelectric polyvinylidene fluoride (PVDF)
  • Tactile sensor

ASJC Scopus subject areas

  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

PVDF-based microfabricated tactile sensor for minimally invasive surgery. / Qasaimeh, Mohammad; Sokhanvar, Saeed; Dargahi, Javad; Kahrizi, Mojtaba.

In: Journal of Microelectromechanical Systems, Vol. 18, No. 1, 01.01.2009, p. 195-207.

Research output: Contribution to journalArticle

Qasaimeh, Mohammad ; Sokhanvar, Saeed ; Dargahi, Javad ; Kahrizi, Mojtaba. / PVDF-based microfabricated tactile sensor for minimally invasive surgery. In: Journal of Microelectromechanical Systems. 2009 ; Vol. 18, No. 1. pp. 195-207.
@article{d35fee41a0984fc88b1b0a97a4fc5c6d,
title = "PVDF-based microfabricated tactile sensor for minimally invasive surgery",
abstract = "This paper aimed to develop a miniaturized tactile sensor capable of measuring force and force position in minimally invasive surgery. The in situ measurement of tactile information is a step forward toward restoring the loss of the sense of touch that has occurred due to shift from traditional to minimally invasive surgeries. The sensor was designed such that it can sense low forces which could be comparable to those produced by pulsating delicate arteries, yet can withstand high forces comparable to grasping forces. The influence of some hidden anatomical features, such as lumps, voids, and arteries, on the stress distribution at the grasping surface was studied. In this paper, the capability of the sensor to determine and locate any point load was also investigated. The proposed sensor was designed and manufactured to be highly sensitive, using polyvinylidene fluoride (PVDF). The microfabrication procedure of the sensor, including corner compensation for toothlike projections and patterning of PVDF film, was discussed. The micromachined sensor was tested, and the experimental results were compared with the results of 3-D finite element modeling.",
keywords = "Microelectromechanical devices, Minimally invasive surgery (MIS), Piezoelectric polyvinylidene fluoride (PVDF), Tactile sensor",
author = "Mohammad Qasaimeh and Saeed Sokhanvar and Javad Dargahi and Mojtaba Kahrizi",
year = "2009",
month = "1",
day = "1",
doi = "10.1109/JMEMS.2008.2008559",
language = "English (US)",
volume = "18",
pages = "195--207",
journal = "Journal of Microelectromechanical Systems",
issn = "1057-7157",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "1",

}

TY - JOUR

T1 - PVDF-based microfabricated tactile sensor for minimally invasive surgery

AU - Qasaimeh, Mohammad

AU - Sokhanvar, Saeed

AU - Dargahi, Javad

AU - Kahrizi, Mojtaba

PY - 2009/1/1

Y1 - 2009/1/1

N2 - This paper aimed to develop a miniaturized tactile sensor capable of measuring force and force position in minimally invasive surgery. The in situ measurement of tactile information is a step forward toward restoring the loss of the sense of touch that has occurred due to shift from traditional to minimally invasive surgeries. The sensor was designed such that it can sense low forces which could be comparable to those produced by pulsating delicate arteries, yet can withstand high forces comparable to grasping forces. The influence of some hidden anatomical features, such as lumps, voids, and arteries, on the stress distribution at the grasping surface was studied. In this paper, the capability of the sensor to determine and locate any point load was also investigated. The proposed sensor was designed and manufactured to be highly sensitive, using polyvinylidene fluoride (PVDF). The microfabrication procedure of the sensor, including corner compensation for toothlike projections and patterning of PVDF film, was discussed. The micromachined sensor was tested, and the experimental results were compared with the results of 3-D finite element modeling.

AB - This paper aimed to develop a miniaturized tactile sensor capable of measuring force and force position in minimally invasive surgery. The in situ measurement of tactile information is a step forward toward restoring the loss of the sense of touch that has occurred due to shift from traditional to minimally invasive surgeries. The sensor was designed such that it can sense low forces which could be comparable to those produced by pulsating delicate arteries, yet can withstand high forces comparable to grasping forces. The influence of some hidden anatomical features, such as lumps, voids, and arteries, on the stress distribution at the grasping surface was studied. In this paper, the capability of the sensor to determine and locate any point load was also investigated. The proposed sensor was designed and manufactured to be highly sensitive, using polyvinylidene fluoride (PVDF). The microfabrication procedure of the sensor, including corner compensation for toothlike projections and patterning of PVDF film, was discussed. The micromachined sensor was tested, and the experimental results were compared with the results of 3-D finite element modeling.

KW - Microelectromechanical devices

KW - Minimally invasive surgery (MIS)

KW - Piezoelectric polyvinylidene fluoride (PVDF)

KW - Tactile sensor

UR - http://www.scopus.com/inward/record.url?scp=60449084174&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=60449084174&partnerID=8YFLogxK

U2 - 10.1109/JMEMS.2008.2008559

DO - 10.1109/JMEMS.2008.2008559

M3 - Article

AN - SCOPUS:60449084174

VL - 18

SP - 195

EP - 207

JO - Journal of Microelectromechanical Systems

JF - Journal of Microelectromechanical Systems

SN - 1057-7157

IS - 1

ER -