Osseointegration of metallic devices: Current trends based on implant hardware design

Paulo Coelho, Ryo Jimbo

Research output: Contribution to journalArticle

Abstract

Osseointegration of metallic devices has been one of the most successful treatments in rehabilitative dentistry and medicine over the past five decades. While highly successful, the quest for designing surgical instrumentation and associated implantable devices that hastens osseointegration has been perpetual and has often been approached as single variable preclinical investigations. The present manuscript presents how the interplay between surgical instrumentation and device macrogeometry not only plays a key role on both early and delayed stages of osseointegration, but may also be key in how efficient smaller length scale designing (at the micrometer and nanometer scale levels) may be in hastening early stages of osseointegration.

Original languageEnglish (US)
Pages (from-to)99-108
Number of pages10
JournalArchives of Biochemistry and Biophysics
Volume561
DOIs
StatePublished - Nov 1 2014

Fingerprint

Osseointegration
Dentistry
Medicine
Hardware
Equipment and Supplies
Manuscripts

Keywords

  • Bone
  • Design
  • Metallic devices
  • Osseointegration

ASJC Scopus subject areas

  • Biochemistry
  • Biophysics
  • Molecular Biology
  • Medicine(all)

Cite this

Osseointegration of metallic devices : Current trends based on implant hardware design. / Coelho, Paulo; Jimbo, Ryo.

In: Archives of Biochemistry and Biophysics, Vol. 561, 01.11.2014, p. 99-108.

Research output: Contribution to journalArticle

@article{b509b1cb77bf4edea722ed467299e904,
title = "Osseointegration of metallic devices: Current trends based on implant hardware design",
abstract = "Osseointegration of metallic devices has been one of the most successful treatments in rehabilitative dentistry and medicine over the past five decades. While highly successful, the quest for designing surgical instrumentation and associated implantable devices that hastens osseointegration has been perpetual and has often been approached as single variable preclinical investigations. The present manuscript presents how the interplay between surgical instrumentation and device macrogeometry not only plays a key role on both early and delayed stages of osseointegration, but may also be key in how efficient smaller length scale designing (at the micrometer and nanometer scale levels) may be in hastening early stages of osseointegration.",
keywords = "Bone, Design, Metallic devices, Osseointegration",
author = "Paulo Coelho and Ryo Jimbo",
year = "2014",
month = "11",
day = "1",
doi = "10.1016/j.abb.2014.06.033",
language = "English (US)",
volume = "561",
pages = "99--108",
journal = "Archives of Biochemistry and Biophysics",
issn = "0003-9861",
publisher = "Academic Press Inc.",

}

TY - JOUR

T1 - Osseointegration of metallic devices

T2 - Current trends based on implant hardware design

AU - Coelho, Paulo

AU - Jimbo, Ryo

PY - 2014/11/1

Y1 - 2014/11/1

N2 - Osseointegration of metallic devices has been one of the most successful treatments in rehabilitative dentistry and medicine over the past five decades. While highly successful, the quest for designing surgical instrumentation and associated implantable devices that hastens osseointegration has been perpetual and has often been approached as single variable preclinical investigations. The present manuscript presents how the interplay between surgical instrumentation and device macrogeometry not only plays a key role on both early and delayed stages of osseointegration, but may also be key in how efficient smaller length scale designing (at the micrometer and nanometer scale levels) may be in hastening early stages of osseointegration.

AB - Osseointegration of metallic devices has been one of the most successful treatments in rehabilitative dentistry and medicine over the past five decades. While highly successful, the quest for designing surgical instrumentation and associated implantable devices that hastens osseointegration has been perpetual and has often been approached as single variable preclinical investigations. The present manuscript presents how the interplay between surgical instrumentation and device macrogeometry not only plays a key role on both early and delayed stages of osseointegration, but may also be key in how efficient smaller length scale designing (at the micrometer and nanometer scale levels) may be in hastening early stages of osseointegration.

KW - Bone

KW - Design

KW - Metallic devices

KW - Osseointegration

UR - http://www.scopus.com/inward/record.url?scp=84907891959&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84907891959&partnerID=8YFLogxK

U2 - 10.1016/j.abb.2014.06.033

DO - 10.1016/j.abb.2014.06.033

M3 - Article

C2 - 25010447

AN - SCOPUS:84907891959

VL - 561

SP - 99

EP - 108

JO - Archives of Biochemistry and Biophysics

JF - Archives of Biochemistry and Biophysics

SN - 0003-9861

ER -