Optimization of dynamic measurement of receptor kinetics by wavelet denoising

Nathaniel M. Alpert, Anthonin Reilhac, Tat C. Chio, Ivan Selesnick

Research output: Contribution to journalArticle

Abstract

The most important technical limitation affecting dynamic measurements with PET is low signal-to-noise ratio (SNR). Several reports have suggested that wavelet processing of receptor kinetic data in the human brain can improve the SNR of parametric images of binding potential (BP). However, it is difficult to fully assess these reports because objective standards have not been developed to measure the tradeoff between accuracy (e.g. degradation of resolution) and precision. This paper employs a realistic simulation method that includes all major elements affecting image formation. The simulation was used to derive an ensemble of dynamic PET ligand (11C-raclopride) experiments that was subjected to wavelet processing. A method for optimizing wavelet denoising is presented and used to analyze the simulated experiments. Using optimized wavelet denoising, SNR of the four-dimensional PET data increased by about a factor of two and SNR of three-dimensional BP maps increased by about a factor of 1.5. Analysis of the difference between the processed and unprocessed means for the 4D concentration data showed that more than 80% of voxels in the ensemble mean of the wavelet processed data deviated by less than 3%. These results show that a 1.5× increase in SNR can be achieved with little degradation of resolution. This corresponds to injecting about twice the radioactivity, a maneuver that is not possible in human studies without saturating the PET camera and/or exposing the subject to more than permitted radioactivity.

Original languageEnglish (US)
Pages (from-to)444-451
Number of pages8
JournalNeuroImage
Volume30
Issue number2
DOIs
StatePublished - Apr 1 2006

Fingerprint

Signal-To-Noise Ratio
Radioactivity
Raclopride
Ligands
Brain

ASJC Scopus subject areas

  • Cognitive Neuroscience
  • Neurology

Cite this

Optimization of dynamic measurement of receptor kinetics by wavelet denoising. / Alpert, Nathaniel M.; Reilhac, Anthonin; Chio, Tat C.; Selesnick, Ivan.

In: NeuroImage, Vol. 30, No. 2, 01.04.2006, p. 444-451.

Research output: Contribution to journalArticle

Alpert, Nathaniel M. ; Reilhac, Anthonin ; Chio, Tat C. ; Selesnick, Ivan. / Optimization of dynamic measurement of receptor kinetics by wavelet denoising. In: NeuroImage. 2006 ; Vol. 30, No. 2. pp. 444-451.
@article{333f2cb1d11749bebebd01bbc8093393,
title = "Optimization of dynamic measurement of receptor kinetics by wavelet denoising",
abstract = "The most important technical limitation affecting dynamic measurements with PET is low signal-to-noise ratio (SNR). Several reports have suggested that wavelet processing of receptor kinetic data in the human brain can improve the SNR of parametric images of binding potential (BP). However, it is difficult to fully assess these reports because objective standards have not been developed to measure the tradeoff between accuracy (e.g. degradation of resolution) and precision. This paper employs a realistic simulation method that includes all major elements affecting image formation. The simulation was used to derive an ensemble of dynamic PET ligand (11C-raclopride) experiments that was subjected to wavelet processing. A method for optimizing wavelet denoising is presented and used to analyze the simulated experiments. Using optimized wavelet denoising, SNR of the four-dimensional PET data increased by about a factor of two and SNR of three-dimensional BP maps increased by about a factor of 1.5. Analysis of the difference between the processed and unprocessed means for the 4D concentration data showed that more than 80{\%} of voxels in the ensemble mean of the wavelet processed data deviated by less than 3{\%}. These results show that a 1.5× increase in SNR can be achieved with little degradation of resolution. This corresponds to injecting about twice the radioactivity, a maneuver that is not possible in human studies without saturating the PET camera and/or exposing the subject to more than permitted radioactivity.",
author = "Alpert, {Nathaniel M.} and Anthonin Reilhac and Chio, {Tat C.} and Ivan Selesnick",
year = "2006",
month = "4",
day = "1",
doi = "10.1016/j.neuroimage.2005.09.031",
language = "English (US)",
volume = "30",
pages = "444--451",
journal = "NeuroImage",
issn = "1053-8119",
publisher = "Academic Press Inc.",
number = "2",

}

TY - JOUR

T1 - Optimization of dynamic measurement of receptor kinetics by wavelet denoising

AU - Alpert, Nathaniel M.

AU - Reilhac, Anthonin

AU - Chio, Tat C.

AU - Selesnick, Ivan

PY - 2006/4/1

Y1 - 2006/4/1

N2 - The most important technical limitation affecting dynamic measurements with PET is low signal-to-noise ratio (SNR). Several reports have suggested that wavelet processing of receptor kinetic data in the human brain can improve the SNR of parametric images of binding potential (BP). However, it is difficult to fully assess these reports because objective standards have not been developed to measure the tradeoff between accuracy (e.g. degradation of resolution) and precision. This paper employs a realistic simulation method that includes all major elements affecting image formation. The simulation was used to derive an ensemble of dynamic PET ligand (11C-raclopride) experiments that was subjected to wavelet processing. A method for optimizing wavelet denoising is presented and used to analyze the simulated experiments. Using optimized wavelet denoising, SNR of the four-dimensional PET data increased by about a factor of two and SNR of three-dimensional BP maps increased by about a factor of 1.5. Analysis of the difference between the processed and unprocessed means for the 4D concentration data showed that more than 80% of voxels in the ensemble mean of the wavelet processed data deviated by less than 3%. These results show that a 1.5× increase in SNR can be achieved with little degradation of resolution. This corresponds to injecting about twice the radioactivity, a maneuver that is not possible in human studies without saturating the PET camera and/or exposing the subject to more than permitted radioactivity.

AB - The most important technical limitation affecting dynamic measurements with PET is low signal-to-noise ratio (SNR). Several reports have suggested that wavelet processing of receptor kinetic data in the human brain can improve the SNR of parametric images of binding potential (BP). However, it is difficult to fully assess these reports because objective standards have not been developed to measure the tradeoff between accuracy (e.g. degradation of resolution) and precision. This paper employs a realistic simulation method that includes all major elements affecting image formation. The simulation was used to derive an ensemble of dynamic PET ligand (11C-raclopride) experiments that was subjected to wavelet processing. A method for optimizing wavelet denoising is presented and used to analyze the simulated experiments. Using optimized wavelet denoising, SNR of the four-dimensional PET data increased by about a factor of two and SNR of three-dimensional BP maps increased by about a factor of 1.5. Analysis of the difference between the processed and unprocessed means for the 4D concentration data showed that more than 80% of voxels in the ensemble mean of the wavelet processed data deviated by less than 3%. These results show that a 1.5× increase in SNR can be achieved with little degradation of resolution. This corresponds to injecting about twice the radioactivity, a maneuver that is not possible in human studies without saturating the PET camera and/or exposing the subject to more than permitted radioactivity.

UR - http://www.scopus.com/inward/record.url?scp=33645116729&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33645116729&partnerID=8YFLogxK

U2 - 10.1016/j.neuroimage.2005.09.031

DO - 10.1016/j.neuroimage.2005.09.031

M3 - Article

C2 - 16257238

AN - SCOPUS:33645116729

VL - 30

SP - 444

EP - 451

JO - NeuroImage

JF - NeuroImage

SN - 1053-8119

IS - 2

ER -