Microleakage of capsulated glass ionomer cements.

W. Scherer, James Kaim, E. Gottlieb-Schein, M. Roffe-Bauer

Research output: Contribution to journalArticle

Abstract

The purpose of this study was to compare marginal leakage in Class V preparations restored and finished within 20 minutes with two different capsulated and syringeable restorative glass ionomer cements. The materials were inserted and finished following manufacturer's specifications. Specimens were thermocycled 125x in fuchsin dye at 5 degrees C and 55 degrees C, mounted in acrylic and sectioned faciolingually. Microleakage was observed and rated on a scale of 0 to 3 at both enamel and cervical margins. The results of this study indicate that: 1) both materials exhibit marginal leakage at enamel and cervical margins, 2) no significant difference in microleakage was found between these materials, and 3) enamel margins leaked less than cementum/dentin margins with each material.

Original languageEnglish (US)
Pages (from-to)355-357
Number of pages3
JournalAmerican Journal of Dentistry
Volume2
Issue number6
StatePublished - Dec 1989

Fingerprint

Glass Ionomer Cements
Dental Enamel
Rosaniline Dyes
Dental Cementum
Dentin
Coloring Agents

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Scherer, W., Kaim, J., Gottlieb-Schein, E., & Roffe-Bauer, M. (1989). Microleakage of capsulated glass ionomer cements. American Journal of Dentistry, 2(6), 355-357.

Microleakage of capsulated glass ionomer cements. / Scherer, W.; Kaim, James; Gottlieb-Schein, E.; Roffe-Bauer, M.

In: American Journal of Dentistry, Vol. 2, No. 6, 12.1989, p. 355-357.

Research output: Contribution to journalArticle

Scherer, W, Kaim, J, Gottlieb-Schein, E & Roffe-Bauer, M 1989, 'Microleakage of capsulated glass ionomer cements.', American Journal of Dentistry, vol. 2, no. 6, pp. 355-357.
Scherer W, Kaim J, Gottlieb-Schein E, Roffe-Bauer M. Microleakage of capsulated glass ionomer cements. American Journal of Dentistry. 1989 Dec;2(6):355-357.
Scherer, W. ; Kaim, James ; Gottlieb-Schein, E. ; Roffe-Bauer, M. / Microleakage of capsulated glass ionomer cements. In: American Journal of Dentistry. 1989 ; Vol. 2, No. 6. pp. 355-357.
@article{d070008f987c4adbbef31dd6f23650e1,
title = "Microleakage of capsulated glass ionomer cements.",
abstract = "The purpose of this study was to compare marginal leakage in Class V preparations restored and finished within 20 minutes with two different capsulated and syringeable restorative glass ionomer cements. The materials were inserted and finished following manufacturer's specifications. Specimens were thermocycled 125x in fuchsin dye at 5 degrees C and 55 degrees C, mounted in acrylic and sectioned faciolingually. Microleakage was observed and rated on a scale of 0 to 3 at both enamel and cervical margins. The results of this study indicate that: 1) both materials exhibit marginal leakage at enamel and cervical margins, 2) no significant difference in microleakage was found between these materials, and 3) enamel margins leaked less than cementum/dentin margins with each material.",
author = "W. Scherer and James Kaim and E. Gottlieb-Schein and M. Roffe-Bauer",
year = "1989",
month = "12",
language = "English (US)",
volume = "2",
pages = "355--357",
journal = "American Journal of Dentistry",
issn = "0894-8275",
publisher = "Mosher and Linder, Inc",
number = "6",

}

TY - JOUR

T1 - Microleakage of capsulated glass ionomer cements.

AU - Scherer, W.

AU - Kaim, James

AU - Gottlieb-Schein, E.

AU - Roffe-Bauer, M.

PY - 1989/12

Y1 - 1989/12

N2 - The purpose of this study was to compare marginal leakage in Class V preparations restored and finished within 20 minutes with two different capsulated and syringeable restorative glass ionomer cements. The materials were inserted and finished following manufacturer's specifications. Specimens were thermocycled 125x in fuchsin dye at 5 degrees C and 55 degrees C, mounted in acrylic and sectioned faciolingually. Microleakage was observed and rated on a scale of 0 to 3 at both enamel and cervical margins. The results of this study indicate that: 1) both materials exhibit marginal leakage at enamel and cervical margins, 2) no significant difference in microleakage was found between these materials, and 3) enamel margins leaked less than cementum/dentin margins with each material.

AB - The purpose of this study was to compare marginal leakage in Class V preparations restored and finished within 20 minutes with two different capsulated and syringeable restorative glass ionomer cements. The materials were inserted and finished following manufacturer's specifications. Specimens were thermocycled 125x in fuchsin dye at 5 degrees C and 55 degrees C, mounted in acrylic and sectioned faciolingually. Microleakage was observed and rated on a scale of 0 to 3 at both enamel and cervical margins. The results of this study indicate that: 1) both materials exhibit marginal leakage at enamel and cervical margins, 2) no significant difference in microleakage was found between these materials, and 3) enamel margins leaked less than cementum/dentin margins with each material.

UR - http://www.scopus.com/inward/record.url?scp=0024822978&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024822978&partnerID=8YFLogxK

M3 - Article

C2 - 2700642

AN - SCOPUS:0024822978

VL - 2

SP - 355

EP - 357

JO - American Journal of Dentistry

JF - American Journal of Dentistry

SN - 0894-8275

IS - 6

ER -