Measurement of rotational temperatures in high-pressure microhollowcathode (MHC) and capillary plasma electrode (CPE) discharges

P. Kurunczi, N. Abramzon, M. Figus, K. Becker

Research output: Contribution to journalArticle

Abstract

We report the results of rotational temperature (TR) measurements in high-pressure (400 Torr) microhollow cathode (MHC) discharges in Ne with a trace admixture of N2 using the unresolved N2 second positive band and the N2 + first negative band. Signičantly different values for TR were obtained for respectively N2 and N 2 + . The rotational temperatures obtained from the analysis of the N2 band system are slightly above room temperature, increase with increasing discharge current, and may be interpreted as the gas kinetic temperature in the MHC discharge plasma. By contrast, the analysis of the N2 + band system yielded rotational temperatures of more than 900 K, which are the result of collisional reaction processes leading to the formation of rotationally excited N2 + ions. The effective lifetime of these ions is comparable to the rotational relaxation time, so that the ions retain much of their rotational excitation prior to emission and are not in thermal equilibrium with the bulk gas. Thus, the TR values obtained for N2 + cannot be equated with the gas kinetic temperature in the plasma. We also carried out a rotational analysis of the unresolved N2 second positive system emitted by an atmospheric-pressure capillary plasma electrode (CPE) discharge in ambient air and measured a temperature of 545 K. This temperature may be close to the gas kinetic temperature as the rotational analysis utilized N2 emissions from inside the capillary which is the region of highest plasma density and highest gas temperature in a CPE discharge.

Original languageEnglish (US)
Pages (from-to)115-124
Number of pages10
JournalActa Physica Slovaca
Volume54
Issue number2
StatePublished - Apr 2004

Fingerprint

plasma electrodes
temperature
gases
kinetics
ions
high temperature gases
admixtures
plasma jets
plasma density
temperature measurement
atmospheric pressure
cathodes
relaxation time

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Measurement of rotational temperatures in high-pressure microhollowcathode (MHC) and capillary plasma electrode (CPE) discharges. / Kurunczi, P.; Abramzon, N.; Figus, M.; Becker, K.

In: Acta Physica Slovaca, Vol. 54, No. 2, 04.2004, p. 115-124.

Research output: Contribution to journalArticle

@article{f3ad8c3c4704408396267c180aba8bdc,
title = "Measurement of rotational temperatures in high-pressure microhollowcathode (MHC) and capillary plasma electrode (CPE) discharges",
abstract = "We report the results of rotational temperature (TR) measurements in high-pressure (400 Torr) microhollow cathode (MHC) discharges in Ne with a trace admixture of N2 using the unresolved N2 second positive band and the N2 + first negative band. Signičantly different values for TR were obtained for respectively N2 and N 2 + . The rotational temperatures obtained from the analysis of the N2 band system are slightly above room temperature, increase with increasing discharge current, and may be interpreted as the gas kinetic temperature in the MHC discharge plasma. By contrast, the analysis of the N2 + band system yielded rotational temperatures of more than 900 K, which are the result of collisional reaction processes leading to the formation of rotationally excited N2 + ions. The effective lifetime of these ions is comparable to the rotational relaxation time, so that the ions retain much of their rotational excitation prior to emission and are not in thermal equilibrium with the bulk gas. Thus, the TR values obtained for N2 + cannot be equated with the gas kinetic temperature in the plasma. We also carried out a rotational analysis of the unresolved N2 second positive system emitted by an atmospheric-pressure capillary plasma electrode (CPE) discharge in ambient air and measured a temperature of 545 K. This temperature may be close to the gas kinetic temperature as the rotational analysis utilized N2 emissions from inside the capillary which is the region of highest plasma density and highest gas temperature in a CPE discharge.",
author = "P. Kurunczi and N. Abramzon and M. Figus and K. Becker",
year = "2004",
month = "4",
language = "English (US)",
volume = "54",
pages = "115--124",
journal = "Acta Physica Slovaca",
issn = "0323-0465",
publisher = "Slovak Academic Press Ltd",
number = "2",

}

TY - JOUR

T1 - Measurement of rotational temperatures in high-pressure microhollowcathode (MHC) and capillary plasma electrode (CPE) discharges

AU - Kurunczi, P.

AU - Abramzon, N.

AU - Figus, M.

AU - Becker, K.

PY - 2004/4

Y1 - 2004/4

N2 - We report the results of rotational temperature (TR) measurements in high-pressure (400 Torr) microhollow cathode (MHC) discharges in Ne with a trace admixture of N2 using the unresolved N2 second positive band and the N2 + first negative band. Signičantly different values for TR were obtained for respectively N2 and N 2 + . The rotational temperatures obtained from the analysis of the N2 band system are slightly above room temperature, increase with increasing discharge current, and may be interpreted as the gas kinetic temperature in the MHC discharge plasma. By contrast, the analysis of the N2 + band system yielded rotational temperatures of more than 900 K, which are the result of collisional reaction processes leading to the formation of rotationally excited N2 + ions. The effective lifetime of these ions is comparable to the rotational relaxation time, so that the ions retain much of their rotational excitation prior to emission and are not in thermal equilibrium with the bulk gas. Thus, the TR values obtained for N2 + cannot be equated with the gas kinetic temperature in the plasma. We also carried out a rotational analysis of the unresolved N2 second positive system emitted by an atmospheric-pressure capillary plasma electrode (CPE) discharge in ambient air and measured a temperature of 545 K. This temperature may be close to the gas kinetic temperature as the rotational analysis utilized N2 emissions from inside the capillary which is the region of highest plasma density and highest gas temperature in a CPE discharge.

AB - We report the results of rotational temperature (TR) measurements in high-pressure (400 Torr) microhollow cathode (MHC) discharges in Ne with a trace admixture of N2 using the unresolved N2 second positive band and the N2 + first negative band. Signičantly different values for TR were obtained for respectively N2 and N 2 + . The rotational temperatures obtained from the analysis of the N2 band system are slightly above room temperature, increase with increasing discharge current, and may be interpreted as the gas kinetic temperature in the MHC discharge plasma. By contrast, the analysis of the N2 + band system yielded rotational temperatures of more than 900 K, which are the result of collisional reaction processes leading to the formation of rotationally excited N2 + ions. The effective lifetime of these ions is comparable to the rotational relaxation time, so that the ions retain much of their rotational excitation prior to emission and are not in thermal equilibrium with the bulk gas. Thus, the TR values obtained for N2 + cannot be equated with the gas kinetic temperature in the plasma. We also carried out a rotational analysis of the unresolved N2 second positive system emitted by an atmospheric-pressure capillary plasma electrode (CPE) discharge in ambient air and measured a temperature of 545 K. This temperature may be close to the gas kinetic temperature as the rotational analysis utilized N2 emissions from inside the capillary which is the region of highest plasma density and highest gas temperature in a CPE discharge.

UR - http://www.scopus.com/inward/record.url?scp=14844310680&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=14844310680&partnerID=8YFLogxK

M3 - Article

VL - 54

SP - 115

EP - 124

JO - Acta Physica Slovaca

JF - Acta Physica Slovaca

SN - 0323-0465

IS - 2

ER -