Magic sandwich echo relaxation mapping of anisotropic systems

Ravinder R. Regatte, Mark E. Schweitzer, Alexej Jerschow, Ravinder Reddy

Research output: Contribution to journalArticle

Abstract

The main objective of this article was (i) to refocus the residual dipolar and quadrupolar interactions in anisotropic tissues employing magic sandwich echo (MSE) imaging and to compare the results with that of conventional spin-echo (SE) imaging, and (ii) to quantify MSE relaxation and dispersion characteristics in bovine Achilles tendon and compare with spin-lattice relaxation time constant in the rotating frame (T). Magic sandwich echo weighted images are ∼75-100% higher in signal-to-noise ratio than the corresponding T2-weighted images. Magic sandwich echo relaxation times varied from 13±2 to 19±3 ms (mean±S.D.), depending upon the structural location of tendon. T2 relaxation times only varied from 4±1 to 10±3 ms (mean±S.D.) on the same corresponding locations. Magic sandwich echo provides ∼100% enhancement in relaxation times compared to T2. Preliminary results based on bovine Achilles tendon and cartilage specimens suggest that the MSE technique has potential for refocusing residual dipolar as well as quadrupolar interactions in anisotropic systems and yields higher intensities than conventional SE imaging as well as T-encoded imaging, especially at low-burst pulse amplitudes (250 and 500 Hz).

Original languageEnglish (US)
Pages (from-to)433-438
Number of pages6
JournalMagnetic Resonance Imaging
Volume25
Issue number3
DOIs
StatePublished - Apr 2007

Fingerprint

Relaxation time
Tendons
echoes
Imaging techniques
Achilles Tendon
tendons
relaxation time
Magnetic Resonance Imaging
Spin-lattice relaxation
Cartilage
Signal-To-Noise Ratio
Signal to noise ratio
Tissue
cartilage
pulse amplitude
spin-lattice relaxation
time constant
bursts
signal to noise ratios
interactions

Keywords

  • Achilles tendon
  • Dipolar contrast
  • Magic sandwich echo

ASJC Scopus subject areas

  • Biophysics
  • Clinical Biochemistry
  • Structural Biology
  • Radiology Nuclear Medicine and imaging
  • Condensed Matter Physics

Cite this

Magic sandwich echo relaxation mapping of anisotropic systems. / Regatte, Ravinder R.; Schweitzer, Mark E.; Jerschow, Alexej; Reddy, Ravinder.

In: Magnetic Resonance Imaging, Vol. 25, No. 3, 04.2007, p. 433-438.

Research output: Contribution to journalArticle

Regatte, Ravinder R. ; Schweitzer, Mark E. ; Jerschow, Alexej ; Reddy, Ravinder. / Magic sandwich echo relaxation mapping of anisotropic systems. In: Magnetic Resonance Imaging. 2007 ; Vol. 25, No. 3. pp. 433-438.
@article{cf2bbac2b85e44f6a13815ae676ef3d3,
title = "Magic sandwich echo relaxation mapping of anisotropic systems",
abstract = "The main objective of this article was (i) to refocus the residual dipolar and quadrupolar interactions in anisotropic tissues employing magic sandwich echo (MSE) imaging and to compare the results with that of conventional spin-echo (SE) imaging, and (ii) to quantify MSE relaxation and dispersion characteristics in bovine Achilles tendon and compare with spin-lattice relaxation time constant in the rotating frame (T1ρ). Magic sandwich echo weighted images are ∼75-100{\%} higher in signal-to-noise ratio than the corresponding T2-weighted images. Magic sandwich echo relaxation times varied from 13±2 to 19±3 ms (mean±S.D.), depending upon the structural location of tendon. T2 relaxation times only varied from 4±1 to 10±3 ms (mean±S.D.) on the same corresponding locations. Magic sandwich echo provides ∼100{\%} enhancement in relaxation times compared to T2. Preliminary results based on bovine Achilles tendon and cartilage specimens suggest that the MSE technique has potential for refocusing residual dipolar as well as quadrupolar interactions in anisotropic systems and yields higher intensities than conventional SE imaging as well as T1ρ-encoded imaging, especially at low-burst pulse amplitudes (250 and 500 Hz).",
keywords = "Achilles tendon, Dipolar contrast, Magic sandwich echo",
author = "Regatte, {Ravinder R.} and Schweitzer, {Mark E.} and Alexej Jerschow and Ravinder Reddy",
year = "2007",
month = "4",
doi = "10.1016/j.mri.2006.09.035",
language = "English (US)",
volume = "25",
pages = "433--438",
journal = "Magnetic Resonance Imaging",
issn = "0730-725X",
publisher = "Elsevier Inc.",
number = "3",

}

TY - JOUR

T1 - Magic sandwich echo relaxation mapping of anisotropic systems

AU - Regatte, Ravinder R.

AU - Schweitzer, Mark E.

AU - Jerschow, Alexej

AU - Reddy, Ravinder

PY - 2007/4

Y1 - 2007/4

N2 - The main objective of this article was (i) to refocus the residual dipolar and quadrupolar interactions in anisotropic tissues employing magic sandwich echo (MSE) imaging and to compare the results with that of conventional spin-echo (SE) imaging, and (ii) to quantify MSE relaxation and dispersion characteristics in bovine Achilles tendon and compare with spin-lattice relaxation time constant in the rotating frame (T1ρ). Magic sandwich echo weighted images are ∼75-100% higher in signal-to-noise ratio than the corresponding T2-weighted images. Magic sandwich echo relaxation times varied from 13±2 to 19±3 ms (mean±S.D.), depending upon the structural location of tendon. T2 relaxation times only varied from 4±1 to 10±3 ms (mean±S.D.) on the same corresponding locations. Magic sandwich echo provides ∼100% enhancement in relaxation times compared to T2. Preliminary results based on bovine Achilles tendon and cartilage specimens suggest that the MSE technique has potential for refocusing residual dipolar as well as quadrupolar interactions in anisotropic systems and yields higher intensities than conventional SE imaging as well as T1ρ-encoded imaging, especially at low-burst pulse amplitudes (250 and 500 Hz).

AB - The main objective of this article was (i) to refocus the residual dipolar and quadrupolar interactions in anisotropic tissues employing magic sandwich echo (MSE) imaging and to compare the results with that of conventional spin-echo (SE) imaging, and (ii) to quantify MSE relaxation and dispersion characteristics in bovine Achilles tendon and compare with spin-lattice relaxation time constant in the rotating frame (T1ρ). Magic sandwich echo weighted images are ∼75-100% higher in signal-to-noise ratio than the corresponding T2-weighted images. Magic sandwich echo relaxation times varied from 13±2 to 19±3 ms (mean±S.D.), depending upon the structural location of tendon. T2 relaxation times only varied from 4±1 to 10±3 ms (mean±S.D.) on the same corresponding locations. Magic sandwich echo provides ∼100% enhancement in relaxation times compared to T2. Preliminary results based on bovine Achilles tendon and cartilage specimens suggest that the MSE technique has potential for refocusing residual dipolar as well as quadrupolar interactions in anisotropic systems and yields higher intensities than conventional SE imaging as well as T1ρ-encoded imaging, especially at low-burst pulse amplitudes (250 and 500 Hz).

KW - Achilles tendon

KW - Dipolar contrast

KW - Magic sandwich echo

UR - http://www.scopus.com/inward/record.url?scp=33947122223&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33947122223&partnerID=8YFLogxK

U2 - 10.1016/j.mri.2006.09.035

DO - 10.1016/j.mri.2006.09.035

M3 - Article

VL - 25

SP - 433

EP - 438

JO - Magnetic Resonance Imaging

JF - Magnetic Resonance Imaging

SN - 0730-725X

IS - 3

ER -