Investigation of micro-scale capillary plasmas for a PDP application

Soo Ho Park, Kwang Sik Lee, Bhum Jae Shin, Steven Kim, Kurt H. Becker, Erich E. Kunhardt

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The properties and characteristics of micro-scale Capillary Plasma Electrode Discharges(CPEDs) were investigated. We examined the basic discharge characteristics of AC-type microscale CPEDs as a function of the L/D ratio. Using the basis of the previous findings, we applied the CPED concept to the design of a commercial plasma display panel and compared the discharge characteristics with those of a conventional DBD-based PDP. The optimum parameters for micro-scale CPED are L/D ratio = ∼0.5, diameter (D) = 125 μm, length (L) = 70 μm, total dielectric thickness (T) = 90 μm. The luminous efficiency of the optimized CPED structure is higher than that of DBD structure with same dielectric thickness. However, by comparison with DBD structure with T= 45 μm which is somewhat higher dielectric thickness than current conventional PDP (T= ∼30 μm) but has almost similar discharge characteristic, there is no noticeable difference in the luminous efficiency.

Original languageEnglish (US)
Title of host publicationDigest of Technical Papers - SID International Symposium
Pages1093-1096
Number of pages4
Volume37
Edition3
StatePublished - 2006
Event44th International Symposium, Seminar, and Exhibition, SID 2006 - San Francisco, CA, United States
Duration: Jun 4 2006Jun 9 2006

Other

Other44th International Symposium, Seminar, and Exhibition, SID 2006
CountryUnited States
CitySan Francisco, CA
Period6/4/066/9/06

Fingerprint

Plasmas
Electrodes
Display devices

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Park, S. H., Lee, K. S., Shin, B. J., Kim, S., Becker, K. H., & Kunhardt, E. E. (2006). Investigation of micro-scale capillary plasmas for a PDP application. In Digest of Technical Papers - SID International Symposium (3 ed., Vol. 37, pp. 1093-1096)

Investigation of micro-scale capillary plasmas for a PDP application. / Park, Soo Ho; Lee, Kwang Sik; Shin, Bhum Jae; Kim, Steven; Becker, Kurt H.; Kunhardt, Erich E.

Digest of Technical Papers - SID International Symposium. Vol. 37 3. ed. 2006. p. 1093-1096.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Park, SH, Lee, KS, Shin, BJ, Kim, S, Becker, KH & Kunhardt, EE 2006, Investigation of micro-scale capillary plasmas for a PDP application. in Digest of Technical Papers - SID International Symposium. 3 edn, vol. 37, pp. 1093-1096, 44th International Symposium, Seminar, and Exhibition, SID 2006, San Francisco, CA, United States, 6/4/06.
Park SH, Lee KS, Shin BJ, Kim S, Becker KH, Kunhardt EE. Investigation of micro-scale capillary plasmas for a PDP application. In Digest of Technical Papers - SID International Symposium. 3 ed. Vol. 37. 2006. p. 1093-1096
Park, Soo Ho ; Lee, Kwang Sik ; Shin, Bhum Jae ; Kim, Steven ; Becker, Kurt H. ; Kunhardt, Erich E. / Investigation of micro-scale capillary plasmas for a PDP application. Digest of Technical Papers - SID International Symposium. Vol. 37 3. ed. 2006. pp. 1093-1096
@inproceedings{e77aa0a9b648494db23b4c3e49869cc1,
title = "Investigation of micro-scale capillary plasmas for a PDP application",
abstract = "The properties and characteristics of micro-scale Capillary Plasma Electrode Discharges(CPEDs) were investigated. We examined the basic discharge characteristics of AC-type microscale CPEDs as a function of the L/D ratio. Using the basis of the previous findings, we applied the CPED concept to the design of a commercial plasma display panel and compared the discharge characteristics with those of a conventional DBD-based PDP. The optimum parameters for micro-scale CPED are L/D ratio = ∼0.5, diameter (D) = 125 μm, length (L) = 70 μm, total dielectric thickness (T) = 90 μm. The luminous efficiency of the optimized CPED structure is higher than that of DBD structure with same dielectric thickness. However, by comparison with DBD structure with T= 45 μm which is somewhat higher dielectric thickness than current conventional PDP (T= ∼30 μm) but has almost similar discharge characteristic, there is no noticeable difference in the luminous efficiency.",
author = "Park, {Soo Ho} and Lee, {Kwang Sik} and Shin, {Bhum Jae} and Steven Kim and Becker, {Kurt H.} and Kunhardt, {Erich E.}",
year = "2006",
language = "English (US)",
volume = "37",
pages = "1093--1096",
booktitle = "Digest of Technical Papers - SID International Symposium",
edition = "3",

}

TY - GEN

T1 - Investigation of micro-scale capillary plasmas for a PDP application

AU - Park, Soo Ho

AU - Lee, Kwang Sik

AU - Shin, Bhum Jae

AU - Kim, Steven

AU - Becker, Kurt H.

AU - Kunhardt, Erich E.

PY - 2006

Y1 - 2006

N2 - The properties and characteristics of micro-scale Capillary Plasma Electrode Discharges(CPEDs) were investigated. We examined the basic discharge characteristics of AC-type microscale CPEDs as a function of the L/D ratio. Using the basis of the previous findings, we applied the CPED concept to the design of a commercial plasma display panel and compared the discharge characteristics with those of a conventional DBD-based PDP. The optimum parameters for micro-scale CPED are L/D ratio = ∼0.5, diameter (D) = 125 μm, length (L) = 70 μm, total dielectric thickness (T) = 90 μm. The luminous efficiency of the optimized CPED structure is higher than that of DBD structure with same dielectric thickness. However, by comparison with DBD structure with T= 45 μm which is somewhat higher dielectric thickness than current conventional PDP (T= ∼30 μm) but has almost similar discharge characteristic, there is no noticeable difference in the luminous efficiency.

AB - The properties and characteristics of micro-scale Capillary Plasma Electrode Discharges(CPEDs) were investigated. We examined the basic discharge characteristics of AC-type microscale CPEDs as a function of the L/D ratio. Using the basis of the previous findings, we applied the CPED concept to the design of a commercial plasma display panel and compared the discharge characteristics with those of a conventional DBD-based PDP. The optimum parameters for micro-scale CPED are L/D ratio = ∼0.5, diameter (D) = 125 μm, length (L) = 70 μm, total dielectric thickness (T) = 90 μm. The luminous efficiency of the optimized CPED structure is higher than that of DBD structure with same dielectric thickness. However, by comparison with DBD structure with T= 45 μm which is somewhat higher dielectric thickness than current conventional PDP (T= ∼30 μm) but has almost similar discharge characteristic, there is no noticeable difference in the luminous efficiency.

UR - http://www.scopus.com/inward/record.url?scp=34547563607&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34547563607&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:34547563607

VL - 37

SP - 1093

EP - 1096

BT - Digest of Technical Papers - SID International Symposium

ER -