Purpose: Based on the current evidence, the effect of implant macrogeometry has a significant influence on osseointegration. Thus, this study evaluated histomorphometrically and histologically the bone response to acid-etched in comparison to grit-blasted/acid-etched (GB) and machined control (C) surfaced implants possessing identical macrogeometry placed in high-density bone. Materials and Methods: Implant surface topography of the 3 different surfaced implants has previously been characterized. The macrogeometry of the implants were conical, and healing chambers were created in the cortical regions. The 3 groups were placed in the external mandibular body of adult male sheep (n = 5). After 6 weeks in vivo, all samples were retrieved for histologic observation and histomorphometry (eg, bone-to-implant contact [BIC] and bone area fraction occupancy [BAFO]). Results: No statistical difference was observed for BIC and for BAFO, although there was a tendency that the mean values for BAFO was higher for the textured surface groups. Conclusions: It is suggested that the effect of surface topography is minimal in high-density bone and osseointegration seemed to be macrogeometry dependent.

Original languageEnglish (US)
Pages (from-to)815-819
Number of pages5
JournalImplant Dentistry
Volume26
Issue number6
DOIs
StatePublished - Dec 1 2017

Fingerprint

Bone Density
Bone and Bones
Acids
Osseointegration
Sheep
Observation

Keywords

  • Biomechanical
  • Dental implants
  • Hybrid-healing pathway
  • Osseointegration
  • Surface

ASJC Scopus subject areas

  • Oral Surgery

Cite this

In vivo evaluation of dual acid-etched and grit-blasted/acid-etched implants with identical macrogeometry in high-density bone. / Jinno, Yohei; Jimbo, Ryo; Tovar, Nick; Teixeira, Hellen S.; Witek, Lukasz; Coelho, Paulo.

In: Implant Dentistry, Vol. 26, No. 6, 01.12.2017, p. 815-819.

Research output: Contribution to journalArticle

@article{3b294ccd1d324315a0a0e011e2cf2d8b,
title = "In vivo evaluation of dual acid-etched and grit-blasted/acid-etched implants with identical macrogeometry in high-density bone",
abstract = "Purpose: Based on the current evidence, the effect of implant macrogeometry has a significant influence on osseointegration. Thus, this study evaluated histomorphometrically and histologically the bone response to acid-etched in comparison to grit-blasted/acid-etched (GB) and machined control (C) surfaced implants possessing identical macrogeometry placed in high-density bone. Materials and Methods: Implant surface topography of the 3 different surfaced implants has previously been characterized. The macrogeometry of the implants were conical, and healing chambers were created in the cortical regions. The 3 groups were placed in the external mandibular body of adult male sheep (n = 5). After 6 weeks in vivo, all samples were retrieved for histologic observation and histomorphometry (eg, bone-to-implant contact [BIC] and bone area fraction occupancy [BAFO]). Results: No statistical difference was observed for BIC and for BAFO, although there was a tendency that the mean values for BAFO was higher for the textured surface groups. Conclusions: It is suggested that the effect of surface topography is minimal in high-density bone and osseointegration seemed to be macrogeometry dependent.",
keywords = "Biomechanical, Dental implants, Hybrid-healing pathway, Osseointegration, Surface",
author = "Yohei Jinno and Ryo Jimbo and Nick Tovar and Teixeira, {Hellen S.} and Lukasz Witek and Paulo Coelho",
year = "2017",
month = "12",
day = "1",
doi = "10.1097/ID.0000000000000672",
language = "English (US)",
volume = "26",
pages = "815--819",
journal = "Implant Dentistry",
issn = "1056-6163",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

TY - JOUR

T1 - In vivo evaluation of dual acid-etched and grit-blasted/acid-etched implants with identical macrogeometry in high-density bone

AU - Jinno, Yohei

AU - Jimbo, Ryo

AU - Tovar, Nick

AU - Teixeira, Hellen S.

AU - Witek, Lukasz

AU - Coelho, Paulo

PY - 2017/12/1

Y1 - 2017/12/1

N2 - Purpose: Based on the current evidence, the effect of implant macrogeometry has a significant influence on osseointegration. Thus, this study evaluated histomorphometrically and histologically the bone response to acid-etched in comparison to grit-blasted/acid-etched (GB) and machined control (C) surfaced implants possessing identical macrogeometry placed in high-density bone. Materials and Methods: Implant surface topography of the 3 different surfaced implants has previously been characterized. The macrogeometry of the implants were conical, and healing chambers were created in the cortical regions. The 3 groups were placed in the external mandibular body of adult male sheep (n = 5). After 6 weeks in vivo, all samples were retrieved for histologic observation and histomorphometry (eg, bone-to-implant contact [BIC] and bone area fraction occupancy [BAFO]). Results: No statistical difference was observed for BIC and for BAFO, although there was a tendency that the mean values for BAFO was higher for the textured surface groups. Conclusions: It is suggested that the effect of surface topography is minimal in high-density bone and osseointegration seemed to be macrogeometry dependent.

AB - Purpose: Based on the current evidence, the effect of implant macrogeometry has a significant influence on osseointegration. Thus, this study evaluated histomorphometrically and histologically the bone response to acid-etched in comparison to grit-blasted/acid-etched (GB) and machined control (C) surfaced implants possessing identical macrogeometry placed in high-density bone. Materials and Methods: Implant surface topography of the 3 different surfaced implants has previously been characterized. The macrogeometry of the implants were conical, and healing chambers were created in the cortical regions. The 3 groups were placed in the external mandibular body of adult male sheep (n = 5). After 6 weeks in vivo, all samples were retrieved for histologic observation and histomorphometry (eg, bone-to-implant contact [BIC] and bone area fraction occupancy [BAFO]). Results: No statistical difference was observed for BIC and for BAFO, although there was a tendency that the mean values for BAFO was higher for the textured surface groups. Conclusions: It is suggested that the effect of surface topography is minimal in high-density bone and osseointegration seemed to be macrogeometry dependent.

KW - Biomechanical

KW - Dental implants

KW - Hybrid-healing pathway

KW - Osseointegration

KW - Surface

UR - http://www.scopus.com/inward/record.url?scp=85051722783&partnerID=8YFLogxK