Immuno-capture of cells in open microfluidics: Microfluidic probes integrated with herringbone micro-mixers

Ayoub Glia, Pavithra Sukumar, Ayoola T. Brimmo, Muhammedin Deliorman, Mohammad Qasaimeh

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Effective capture of cancer cells from whole peripheral blood samples, i.e. circulating tumor cells (CTCs), is still an existing limitation for liquid biopsy-based diagnostics. The well-established closed-channel herringbone micro-mixers are one of the widely adopted methods for isolating CTCs based on antigen-antibody interaction. However, they are known to be associated with several drawbacks, such as limited capture areas within the channels, restricted access to isolated cells, difficulties to achieve multiplexed antibody capture assays for immuno-phenotyping, and limited postprocessing possibilities. To tackle these issues, we developed a novel microfluidic probe (MFP) that is integrated with herringbone micro-mixers on its tip surface (HMFP). The tip surface was designed with 2-slitted apertures, one for injecting the cell suspension and the other for performing high flow rate aspiration to confine the flow. The herringbone mixing elements were distributed in-between the apertures for micro-mixing that enhances the CTCs capture on the antibodies-coated bottom glass surface. Unlike the closed herringbone chips, the functionalized bottom glass surface was kept large given the capacity for the MFP to work in scanning mode, and so it prevented cell capture saturation effect. Our MFP design and experimental setup showed a cell capture efficiency of 59-81% with flow rates of 0.6-2.4 mL/h. The capture of CTCs in an open microfluidic system allows for easy post-process and CTC analysis, such as single cell drug testing and mechano-phenotyping using atomic force microscopy.

Original languageEnglish (US)
Title of host publicationMicrofluidics, BioMEMS, and Medical Microsystems XVII
EditorsHolger Becker, Bonnie L. Gray
PublisherSPIE
ISBN (Electronic)9781510623927
DOIs
StatePublished - Jan 1 2019
EventMicrofluidics, BioMEMS, and Medical Microsystems XVII 2019 - San Francisco, United States
Duration: Feb 2 2019Feb 4 2019

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10875
ISSN (Print)1605-7422

Conference

ConferenceMicrofluidics, BioMEMS, and Medical Microsystems XVII 2019
CountryUnited States
CitySan Francisco
Period2/2/192/4/19

Fingerprint

Microfluidics
Circulating Neoplastic Cells
Tumors
tumors
Antibodies
probes
cells
antibodies
Glass
Cells
Flow rate
flow velocity
apertures
Biopsy
Antigens
glass
Atomic Force Microscopy
antigens
Assays
Atomic force microscopy

Keywords

  • 3D printing
  • Circulating tumor cell
  • Herringbone
  • Liquid biopsy
  • Micro-mixer
  • Microfluidic
  • Probe

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Cite this

Glia, A., Sukumar, P., Brimmo, A. T., Deliorman, M., & Qasaimeh, M. (2019). Immuno-capture of cells in open microfluidics: Microfluidic probes integrated with herringbone micro-mixers. In H. Becker, & B. L. Gray (Eds.), Microfluidics, BioMEMS, and Medical Microsystems XVII [108751F] (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Vol. 10875). SPIE. https://doi.org/10.1117/12.2516035

Immuno-capture of cells in open microfluidics : Microfluidic probes integrated with herringbone micro-mixers. / Glia, Ayoub; Sukumar, Pavithra; Brimmo, Ayoola T.; Deliorman, Muhammedin; Qasaimeh, Mohammad.

Microfluidics, BioMEMS, and Medical Microsystems XVII. ed. / Holger Becker; Bonnie L. Gray. SPIE, 2019. 108751F (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Vol. 10875).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Glia, A, Sukumar, P, Brimmo, AT, Deliorman, M & Qasaimeh, M 2019, Immuno-capture of cells in open microfluidics: Microfluidic probes integrated with herringbone micro-mixers. in H Becker & BL Gray (eds), Microfluidics, BioMEMS, and Medical Microsystems XVII., 108751F, Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 10875, SPIE, Microfluidics, BioMEMS, and Medical Microsystems XVII 2019, San Francisco, United States, 2/2/19. https://doi.org/10.1117/12.2516035
Glia A, Sukumar P, Brimmo AT, Deliorman M, Qasaimeh M. Immuno-capture of cells in open microfluidics: Microfluidic probes integrated with herringbone micro-mixers. In Becker H, Gray BL, editors, Microfluidics, BioMEMS, and Medical Microsystems XVII. SPIE. 2019. 108751F. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE). https://doi.org/10.1117/12.2516035
Glia, Ayoub ; Sukumar, Pavithra ; Brimmo, Ayoola T. ; Deliorman, Muhammedin ; Qasaimeh, Mohammad. / Immuno-capture of cells in open microfluidics : Microfluidic probes integrated with herringbone micro-mixers. Microfluidics, BioMEMS, and Medical Microsystems XVII. editor / Holger Becker ; Bonnie L. Gray. SPIE, 2019. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE).
@inproceedings{e4c33cdd0ec5480282907381bf5a2d1b,
title = "Immuno-capture of cells in open microfluidics: Microfluidic probes integrated with herringbone micro-mixers",
abstract = "Effective capture of cancer cells from whole peripheral blood samples, i.e. circulating tumor cells (CTCs), is still an existing limitation for liquid biopsy-based diagnostics. The well-established closed-channel herringbone micro-mixers are one of the widely adopted methods for isolating CTCs based on antigen-antibody interaction. However, they are known to be associated with several drawbacks, such as limited capture areas within the channels, restricted access to isolated cells, difficulties to achieve multiplexed antibody capture assays for immuno-phenotyping, and limited postprocessing possibilities. To tackle these issues, we developed a novel microfluidic probe (MFP) that is integrated with herringbone micro-mixers on its tip surface (HMFP). The tip surface was designed with 2-slitted apertures, one for injecting the cell suspension and the other for performing high flow rate aspiration to confine the flow. The herringbone mixing elements were distributed in-between the apertures for micro-mixing that enhances the CTCs capture on the antibodies-coated bottom glass surface. Unlike the closed herringbone chips, the functionalized bottom glass surface was kept large given the capacity for the MFP to work in scanning mode, and so it prevented cell capture saturation effect. Our MFP design and experimental setup showed a cell capture efficiency of 59-81{\%} with flow rates of 0.6-2.4 mL/h. The capture of CTCs in an open microfluidic system allows for easy post-process and CTC analysis, such as single cell drug testing and mechano-phenotyping using atomic force microscopy.",
keywords = "3D printing, Circulating tumor cell, Herringbone, Liquid biopsy, Micro-mixer, Microfluidic, Probe",
author = "Ayoub Glia and Pavithra Sukumar and Brimmo, {Ayoola T.} and Muhammedin Deliorman and Mohammad Qasaimeh",
year = "2019",
month = "1",
day = "1",
doi = "10.1117/12.2516035",
language = "English (US)",
series = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",
publisher = "SPIE",
editor = "Holger Becker and Gray, {Bonnie L.}",
booktitle = "Microfluidics, BioMEMS, and Medical Microsystems XVII",

}

TY - GEN

T1 - Immuno-capture of cells in open microfluidics

T2 - Microfluidic probes integrated with herringbone micro-mixers

AU - Glia, Ayoub

AU - Sukumar, Pavithra

AU - Brimmo, Ayoola T.

AU - Deliorman, Muhammedin

AU - Qasaimeh, Mohammad

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Effective capture of cancer cells from whole peripheral blood samples, i.e. circulating tumor cells (CTCs), is still an existing limitation for liquid biopsy-based diagnostics. The well-established closed-channel herringbone micro-mixers are one of the widely adopted methods for isolating CTCs based on antigen-antibody interaction. However, they are known to be associated with several drawbacks, such as limited capture areas within the channels, restricted access to isolated cells, difficulties to achieve multiplexed antibody capture assays for immuno-phenotyping, and limited postprocessing possibilities. To tackle these issues, we developed a novel microfluidic probe (MFP) that is integrated with herringbone micro-mixers on its tip surface (HMFP). The tip surface was designed with 2-slitted apertures, one for injecting the cell suspension and the other for performing high flow rate aspiration to confine the flow. The herringbone mixing elements were distributed in-between the apertures for micro-mixing that enhances the CTCs capture on the antibodies-coated bottom glass surface. Unlike the closed herringbone chips, the functionalized bottom glass surface was kept large given the capacity for the MFP to work in scanning mode, and so it prevented cell capture saturation effect. Our MFP design and experimental setup showed a cell capture efficiency of 59-81% with flow rates of 0.6-2.4 mL/h. The capture of CTCs in an open microfluidic system allows for easy post-process and CTC analysis, such as single cell drug testing and mechano-phenotyping using atomic force microscopy.

AB - Effective capture of cancer cells from whole peripheral blood samples, i.e. circulating tumor cells (CTCs), is still an existing limitation for liquid biopsy-based diagnostics. The well-established closed-channel herringbone micro-mixers are one of the widely adopted methods for isolating CTCs based on antigen-antibody interaction. However, they are known to be associated with several drawbacks, such as limited capture areas within the channels, restricted access to isolated cells, difficulties to achieve multiplexed antibody capture assays for immuno-phenotyping, and limited postprocessing possibilities. To tackle these issues, we developed a novel microfluidic probe (MFP) that is integrated with herringbone micro-mixers on its tip surface (HMFP). The tip surface was designed with 2-slitted apertures, one for injecting the cell suspension and the other for performing high flow rate aspiration to confine the flow. The herringbone mixing elements were distributed in-between the apertures for micro-mixing that enhances the CTCs capture on the antibodies-coated bottom glass surface. Unlike the closed herringbone chips, the functionalized bottom glass surface was kept large given the capacity for the MFP to work in scanning mode, and so it prevented cell capture saturation effect. Our MFP design and experimental setup showed a cell capture efficiency of 59-81% with flow rates of 0.6-2.4 mL/h. The capture of CTCs in an open microfluidic system allows for easy post-process and CTC analysis, such as single cell drug testing and mechano-phenotyping using atomic force microscopy.

KW - 3D printing

KW - Circulating tumor cell

KW - Herringbone

KW - Liquid biopsy

KW - Micro-mixer

KW - Microfluidic

KW - Probe

UR - http://www.scopus.com/inward/record.url?scp=85066601110&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85066601110&partnerID=8YFLogxK

U2 - 10.1117/12.2516035

DO - 10.1117/12.2516035

M3 - Conference contribution

AN - SCOPUS:85066601110

T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

BT - Microfluidics, BioMEMS, and Medical Microsystems XVII

A2 - Becker, Holger

A2 - Gray, Bonnie L.

PB - SPIE

ER -