    This paper presents the results of a large-scale experimental program aiming to study the behavior of reinforced concrete (RC) columns under simulated seismic loading, strengthened in flexure (of crucial importance in capacity design) with different types and configurations of near-surface-mounted (NSM) reinforcing materials. The role of different parameters is examined by comparing lateral load-versus-displacement response characteristics (peak force, drift ratios, energy dissipation, and stiffness). Those parameters are as follows: carbon or glass fiber-reinforced polymers (FRP) versus stainless steel, configuration and amount of NSM reinforcement, confinement via local jacketing, and type of bonding agent (epoxy resin or mortar). The results demonstrate that NSM FRP and stainless steel reinforcement is a viable solution toward enhancing the flexural resistance of RC columns subjected to seismic loads. This is especially the case when the retrofitting scheme combines epoxy-bonded NSM bars with local confining jackets (provided in this study with textile-reinforced mortars [TRM]).

    Original languageEnglish (US)
    Pages (from-to)495-505
    Number of pages11
    JournalACI Structural Journal
    Volume106
    Issue number4
    StatePublished - Jul 1 2009

    Fingerprint

    Reinforced concrete
    Stainless steel
    Fibers
    Polymers
    Mortar
    Reinforcement
    Retrofitting
    Epoxy resins
    Glass fibers
    Carbon fibers
    Energy dissipation
    Textiles
    Stiffness

    Keywords

    • Columns
    • Flexure
    • Near-surface-mounted reinforcement
    • Seismic retrofitting
    • Strengthening
    • Textile-reinforced mortar

    ASJC Scopus subject areas

    • Civil and Structural Engineering
    • Building and Construction

    Cite this

    Flexural strengthening of reinforced concrete columns with near-surface-mounted FRP or stainless steel. / Bournas, Dionysios A.; Triantafillou, Thanasis.

    In: ACI Structural Journal, Vol. 106, No. 4, 01.07.2009, p. 495-505.

    Research output: Contribution to journalArticle

    @article{a21d097d933d489cb2ddca7f2c1383d6,
    title = "Flexural strengthening of reinforced concrete columns with near-surface-mounted FRP or stainless steel",
    abstract = "This paper presents the results of a large-scale experimental program aiming to study the behavior of reinforced concrete (RC) columns under simulated seismic loading, strengthened in flexure (of crucial importance in capacity design) with different types and configurations of near-surface-mounted (NSM) reinforcing materials. The role of different parameters is examined by comparing lateral load-versus-displacement response characteristics (peak force, drift ratios, energy dissipation, and stiffness). Those parameters are as follows: carbon or glass fiber-reinforced polymers (FRP) versus stainless steel, configuration and amount of NSM reinforcement, confinement via local jacketing, and type of bonding agent (epoxy resin or mortar). The results demonstrate that NSM FRP and stainless steel reinforcement is a viable solution toward enhancing the flexural resistance of RC columns subjected to seismic loads. This is especially the case when the retrofitting scheme combines epoxy-bonded NSM bars with local confining jackets (provided in this study with textile-reinforced mortars [TRM]).",
    keywords = "Columns, Flexure, Near-surface-mounted reinforcement, Seismic retrofitting, Strengthening, Textile-reinforced mortar",
    author = "Bournas, {Dionysios A.} and Thanasis Triantafillou",
    year = "2009",
    month = "7",
    day = "1",
    language = "English (US)",
    volume = "106",
    pages = "495--505",
    journal = "ACI Structural Journal",
    issn = "0889-3241",
    publisher = "American Concrete Institute",
    number = "4",

    }

    TY - JOUR

    T1 - Flexural strengthening of reinforced concrete columns with near-surface-mounted FRP or stainless steel

    AU - Bournas, Dionysios A.

    AU - Triantafillou, Thanasis

    PY - 2009/7/1

    Y1 - 2009/7/1

    N2 - This paper presents the results of a large-scale experimental program aiming to study the behavior of reinforced concrete (RC) columns under simulated seismic loading, strengthened in flexure (of crucial importance in capacity design) with different types and configurations of near-surface-mounted (NSM) reinforcing materials. The role of different parameters is examined by comparing lateral load-versus-displacement response characteristics (peak force, drift ratios, energy dissipation, and stiffness). Those parameters are as follows: carbon or glass fiber-reinforced polymers (FRP) versus stainless steel, configuration and amount of NSM reinforcement, confinement via local jacketing, and type of bonding agent (epoxy resin or mortar). The results demonstrate that NSM FRP and stainless steel reinforcement is a viable solution toward enhancing the flexural resistance of RC columns subjected to seismic loads. This is especially the case when the retrofitting scheme combines epoxy-bonded NSM bars with local confining jackets (provided in this study with textile-reinforced mortars [TRM]).

    AB - This paper presents the results of a large-scale experimental program aiming to study the behavior of reinforced concrete (RC) columns under simulated seismic loading, strengthened in flexure (of crucial importance in capacity design) with different types and configurations of near-surface-mounted (NSM) reinforcing materials. The role of different parameters is examined by comparing lateral load-versus-displacement response characteristics (peak force, drift ratios, energy dissipation, and stiffness). Those parameters are as follows: carbon or glass fiber-reinforced polymers (FRP) versus stainless steel, configuration and amount of NSM reinforcement, confinement via local jacketing, and type of bonding agent (epoxy resin or mortar). The results demonstrate that NSM FRP and stainless steel reinforcement is a viable solution toward enhancing the flexural resistance of RC columns subjected to seismic loads. This is especially the case when the retrofitting scheme combines epoxy-bonded NSM bars with local confining jackets (provided in this study with textile-reinforced mortars [TRM]).

    KW - Columns

    KW - Flexure

    KW - Near-surface-mounted reinforcement

    KW - Seismic retrofitting

    KW - Strengthening

    KW - Textile-reinforced mortar

    UR - http://www.scopus.com/inward/record.url?scp=70449347262&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=70449347262&partnerID=8YFLogxK

    M3 - Article

    AN - SCOPUS:70449347262

    VL - 106

    SP - 495

    EP - 505

    JO - ACI Structural Journal

    JF - ACI Structural Journal

    SN - 0889-3241

    IS - 4

    ER -