Evaluation of the marginal seal of CEREC 3D restorations using two different luting agents

Leila Jahangiri, Claudine Agosta, Denise Estafan

Research output: Contribution to journalArticle

Abstract

This in vitro study used two resin cements to evaluate the microleakage of CEREC 3D restorations. An mesio-occluso-distal-lingual (MODL) onlay preparation was placed on an ivorine premolar tooth. Sixty elastomeric impressions of this preparation were used to fabricate resin dies. Imaging propellant was applied to the resin dies. Optical impressions were taken with the CEREC 3 and the CEREC 3D software and used to design and mill 60 onlays. The reliability coefficient was α = 0.76 with an examiner agreement rate of 96.4%. Restorations cemented with posterior composite demonstrated a mean microleakage value of 1.46 mm (SD ± 1.64); by contrast, those restored with dual-cure cement reported a mean microleakage value of 0.21 mm (SD ± 0.57). The difference in microleakage was very highly significant (α = 0.001). Posterior composite CEREC 3D restorations cemented with the dual-cure cement showed significantly less microleakage compared to those cemented with posterior composite.

Original languageEnglish (US)
Pages (from-to)117-120
Number of pages4
JournalGeneral Dentistry
Volume55
Issue number2
StatePublished - Mar 2007

Fingerprint

Dental Cements
Inlays
Resin Cements
Bicuspid
Tongue
Tooth
Software
Dual Cement
In Vitro Techniques
elastomeric

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Evaluation of the marginal seal of CEREC 3D restorations using two different luting agents. / Jahangiri, Leila; Agosta, Claudine; Estafan, Denise.

In: General Dentistry, Vol. 55, No. 2, 03.2007, p. 117-120.

Research output: Contribution to journalArticle

@article{7e873bb701d54222beddd89e01e1e31e,
title = "Evaluation of the marginal seal of CEREC 3D restorations using two different luting agents",
abstract = "This in vitro study used two resin cements to evaluate the microleakage of CEREC 3D restorations. An mesio-occluso-distal-lingual (MODL) onlay preparation was placed on an ivorine premolar tooth. Sixty elastomeric impressions of this preparation were used to fabricate resin dies. Imaging propellant was applied to the resin dies. Optical impressions were taken with the CEREC 3 and the CEREC 3D software and used to design and mill 60 onlays. The reliability coefficient was α = 0.76 with an examiner agreement rate of 96.4{\%}. Restorations cemented with posterior composite demonstrated a mean microleakage value of 1.46 mm (SD ± 1.64); by contrast, those restored with dual-cure cement reported a mean microleakage value of 0.21 mm (SD ± 0.57). The difference in microleakage was very highly significant (α = 0.001). Posterior composite CEREC 3D restorations cemented with the dual-cure cement showed significantly less microleakage compared to those cemented with posterior composite.",
author = "Leila Jahangiri and Claudine Agosta and Denise Estafan",
year = "2007",
month = "3",
language = "English (US)",
volume = "55",
pages = "117--120",
journal = "General Dentistry",
issn = "0363-6771",
publisher = "Academy of General Dentistry",
number = "2",

}

TY - JOUR

T1 - Evaluation of the marginal seal of CEREC 3D restorations using two different luting agents

AU - Jahangiri, Leila

AU - Agosta, Claudine

AU - Estafan, Denise

PY - 2007/3

Y1 - 2007/3

N2 - This in vitro study used two resin cements to evaluate the microleakage of CEREC 3D restorations. An mesio-occluso-distal-lingual (MODL) onlay preparation was placed on an ivorine premolar tooth. Sixty elastomeric impressions of this preparation were used to fabricate resin dies. Imaging propellant was applied to the resin dies. Optical impressions were taken with the CEREC 3 and the CEREC 3D software and used to design and mill 60 onlays. The reliability coefficient was α = 0.76 with an examiner agreement rate of 96.4%. Restorations cemented with posterior composite demonstrated a mean microleakage value of 1.46 mm (SD ± 1.64); by contrast, those restored with dual-cure cement reported a mean microleakage value of 0.21 mm (SD ± 0.57). The difference in microleakage was very highly significant (α = 0.001). Posterior composite CEREC 3D restorations cemented with the dual-cure cement showed significantly less microleakage compared to those cemented with posterior composite.

AB - This in vitro study used two resin cements to evaluate the microleakage of CEREC 3D restorations. An mesio-occluso-distal-lingual (MODL) onlay preparation was placed on an ivorine premolar tooth. Sixty elastomeric impressions of this preparation were used to fabricate resin dies. Imaging propellant was applied to the resin dies. Optical impressions were taken with the CEREC 3 and the CEREC 3D software and used to design and mill 60 onlays. The reliability coefficient was α = 0.76 with an examiner agreement rate of 96.4%. Restorations cemented with posterior composite demonstrated a mean microleakage value of 1.46 mm (SD ± 1.64); by contrast, those restored with dual-cure cement reported a mean microleakage value of 0.21 mm (SD ± 0.57). The difference in microleakage was very highly significant (α = 0.001). Posterior composite CEREC 3D restorations cemented with the dual-cure cement showed significantly less microleakage compared to those cemented with posterior composite.

UR - http://www.scopus.com/inward/record.url?scp=33847649956&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33847649956&partnerID=8YFLogxK

M3 - Article

VL - 55

SP - 117

EP - 120

JO - General Dentistry

JF - General Dentistry

SN - 0363-6771