Estimation of design parameters of single-phase distribution transformers from terminal measurements

Reza Kazemi, Saeed Jazebi, Digvijay Deswal, Francisco De Leon

Research output: Contribution to journalArticle

Abstract

In this paper, a novel method is proposed for the estimation of the design parameters of single-phase distribution transformers using data acquired from terminal measurements along with nameplate data and external tank dimensions. Transformer parameters that can be measured from terminals, for example, leakage inductance, saturation inductance, andwinding resistance, are considered first. These parameters are analytically correlated with the geometrical information of the transformer structure. A system of nonlinear equations is derived accordingly. Winding dimensions and the number of turns are computed with acceptable engineering accuracy. The core dimensions (including its crosssectional area) are calculated using winding information. The obtained data can be utilized to develop white- or gray-box models to be used in the investigation of the thermal and/or electromagnetic behavior of power transformers as presented in several research studies published to date.Examples on laboratory and utility-grade transformers are shown for illustration and validation of the proposed design parameter estimation method.

Original languageEnglish (US)
Article number7707337
Pages (from-to)2031-2039
Number of pages9
JournalIEEE Transactions on Power Delivery
Volume32
Issue number4
DOIs
StatePublished - Aug 1 2017

Fingerprint

Inductance
Nameplates
Power transformers
Nonlinear equations
Parameter estimation
Hot Temperature

Keywords

  • Leakage inductance
  • Parameter estimation
  • Saturation inductance
  • Transformer design

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Estimation of design parameters of single-phase distribution transformers from terminal measurements. / Kazemi, Reza; Jazebi, Saeed; Deswal, Digvijay; De Leon, Francisco.

In: IEEE Transactions on Power Delivery, Vol. 32, No. 4, 7707337, 01.08.2017, p. 2031-2039.

Research output: Contribution to journalArticle

@article{cccb0f9ce583419f84cef03f012176a0,
title = "Estimation of design parameters of single-phase distribution transformers from terminal measurements",
abstract = "In this paper, a novel method is proposed for the estimation of the design parameters of single-phase distribution transformers using data acquired from terminal measurements along with nameplate data and external tank dimensions. Transformer parameters that can be measured from terminals, for example, leakage inductance, saturation inductance, andwinding resistance, are considered first. These parameters are analytically correlated with the geometrical information of the transformer structure. A system of nonlinear equations is derived accordingly. Winding dimensions and the number of turns are computed with acceptable engineering accuracy. The core dimensions (including its crosssectional area) are calculated using winding information. The obtained data can be utilized to develop white- or gray-box models to be used in the investigation of the thermal and/or electromagnetic behavior of power transformers as presented in several research studies published to date.Examples on laboratory and utility-grade transformers are shown for illustration and validation of the proposed design parameter estimation method.",
keywords = "Leakage inductance, Parameter estimation, Saturation inductance, Transformer design",
author = "Reza Kazemi and Saeed Jazebi and Digvijay Deswal and {De Leon}, Francisco",
year = "2017",
month = "8",
day = "1",
doi = "10.1109/TPWRD.2016.2621753",
language = "English (US)",
volume = "32",
pages = "2031--2039",
journal = "IEEE Transactions on Power Delivery",
issn = "0885-8977",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "4",

}

TY - JOUR

T1 - Estimation of design parameters of single-phase distribution transformers from terminal measurements

AU - Kazemi, Reza

AU - Jazebi, Saeed

AU - Deswal, Digvijay

AU - De Leon, Francisco

PY - 2017/8/1

Y1 - 2017/8/1

N2 - In this paper, a novel method is proposed for the estimation of the design parameters of single-phase distribution transformers using data acquired from terminal measurements along with nameplate data and external tank dimensions. Transformer parameters that can be measured from terminals, for example, leakage inductance, saturation inductance, andwinding resistance, are considered first. These parameters are analytically correlated with the geometrical information of the transformer structure. A system of nonlinear equations is derived accordingly. Winding dimensions and the number of turns are computed with acceptable engineering accuracy. The core dimensions (including its crosssectional area) are calculated using winding information. The obtained data can be utilized to develop white- or gray-box models to be used in the investigation of the thermal and/or electromagnetic behavior of power transformers as presented in several research studies published to date.Examples on laboratory and utility-grade transformers are shown for illustration and validation of the proposed design parameter estimation method.

AB - In this paper, a novel method is proposed for the estimation of the design parameters of single-phase distribution transformers using data acquired from terminal measurements along with nameplate data and external tank dimensions. Transformer parameters that can be measured from terminals, for example, leakage inductance, saturation inductance, andwinding resistance, are considered first. These parameters are analytically correlated with the geometrical information of the transformer structure. A system of nonlinear equations is derived accordingly. Winding dimensions and the number of turns are computed with acceptable engineering accuracy. The core dimensions (including its crosssectional area) are calculated using winding information. The obtained data can be utilized to develop white- or gray-box models to be used in the investigation of the thermal and/or electromagnetic behavior of power transformers as presented in several research studies published to date.Examples on laboratory and utility-grade transformers are shown for illustration and validation of the proposed design parameter estimation method.

KW - Leakage inductance

KW - Parameter estimation

KW - Saturation inductance

KW - Transformer design

UR - http://www.scopus.com/inward/record.url?scp=85021725984&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85021725984&partnerID=8YFLogxK

U2 - 10.1109/TPWRD.2016.2621753

DO - 10.1109/TPWRD.2016.2621753

M3 - Article

AN - SCOPUS:85021725984

VL - 32

SP - 2031

EP - 2039

JO - IEEE Transactions on Power Delivery

JF - IEEE Transactions on Power Delivery

SN - 0885-8977

IS - 4

M1 - 7707337