Enhancing the quality of infrared-based automatic pedestrian sensor data by nonparametric statistical method

Hong Yang, Kaan Ozbay, Bekir Bartin

Research output: Contribution to journalArticle

Abstract

With the advent of intelligent transportation systems in the past several decades, sensors are being extensively used to detect and count vehicle movements. The use of similar sensing technologies to detect pedestrian movements, however, is relatively new. Pedestrian counts are essential for decision making in pedestrian facility planning, signal timing, and pedestrian safety modeling. Conventional methods such as manual counting and videotaping can hardly satisfy the requirements of programs for the long-term collection of pedestrian data. Advances in sensing technologies have increased the ability to automate pedestrian data collection with the use of infrared sensors. However, the quality of the data from infrared sensors is still a problem; several field studies have shown that these types of sensors do not always perform perfectly. Field tests conducted in this study and by other research teams showed that infrared sensors usually counted significantly fewer pedestrians than the actual number. Thus, the quality of the data from infrared sensors needs to be enhanced. This paper proposes a nonparametric statistical method to calibrate raw sensor data to achieve this goal. A bivariate bootstrap sampling procedure was used to obtain correction factors for new counts instead of the traditional regression-based approach. Two case studies were used to test the validation of the proposed calibration procedure. Test results showed that the proposed procedure could improve the quality of the sensor data by reducing the discrepancy between sensor counts and ground truth (true) data. The transferability of the calibration procedure was also verified through the case studies.

Original languageEnglish (US)
Pages (from-to)11-17
Number of pages7
JournalTransportation Research Record
Issue number2264
DOIs
StatePublished - Dec 1 2011

Fingerprint

Statistical methods
Infrared radiation
Sensors
Pedestrian safety
Calibration
Decision making
Sampling
Planning

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Mechanical Engineering

Cite this

Enhancing the quality of infrared-based automatic pedestrian sensor data by nonparametric statistical method. / Yang, Hong; Ozbay, Kaan; Bartin, Bekir.

In: Transportation Research Record, No. 2264, 01.12.2011, p. 11-17.

Research output: Contribution to journalArticle

@article{2aaf464d77a24934b783bba5fe355f6e,
title = "Enhancing the quality of infrared-based automatic pedestrian sensor data by nonparametric statistical method",
abstract = "With the advent of intelligent transportation systems in the past several decades, sensors are being extensively used to detect and count vehicle movements. The use of similar sensing technologies to detect pedestrian movements, however, is relatively new. Pedestrian counts are essential for decision making in pedestrian facility planning, signal timing, and pedestrian safety modeling. Conventional methods such as manual counting and videotaping can hardly satisfy the requirements of programs for the long-term collection of pedestrian data. Advances in sensing technologies have increased the ability to automate pedestrian data collection with the use of infrared sensors. However, the quality of the data from infrared sensors is still a problem; several field studies have shown that these types of sensors do not always perform perfectly. Field tests conducted in this study and by other research teams showed that infrared sensors usually counted significantly fewer pedestrians than the actual number. Thus, the quality of the data from infrared sensors needs to be enhanced. This paper proposes a nonparametric statistical method to calibrate raw sensor data to achieve this goal. A bivariate bootstrap sampling procedure was used to obtain correction factors for new counts instead of the traditional regression-based approach. Two case studies were used to test the validation of the proposed calibration procedure. Test results showed that the proposed procedure could improve the quality of the sensor data by reducing the discrepancy between sensor counts and ground truth (true) data. The transferability of the calibration procedure was also verified through the case studies.",
author = "Hong Yang and Kaan Ozbay and Bekir Bartin",
year = "2011",
month = "12",
day = "1",
doi = "10.3141/2264-02",
language = "English (US)",
pages = "11--17",
journal = "Transportation Research Record",
issn = "0361-1981",
publisher = "US National Research Council",
number = "2264",

}

TY - JOUR

T1 - Enhancing the quality of infrared-based automatic pedestrian sensor data by nonparametric statistical method

AU - Yang, Hong

AU - Ozbay, Kaan

AU - Bartin, Bekir

PY - 2011/12/1

Y1 - 2011/12/1

N2 - With the advent of intelligent transportation systems in the past several decades, sensors are being extensively used to detect and count vehicle movements. The use of similar sensing technologies to detect pedestrian movements, however, is relatively new. Pedestrian counts are essential for decision making in pedestrian facility planning, signal timing, and pedestrian safety modeling. Conventional methods such as manual counting and videotaping can hardly satisfy the requirements of programs for the long-term collection of pedestrian data. Advances in sensing technologies have increased the ability to automate pedestrian data collection with the use of infrared sensors. However, the quality of the data from infrared sensors is still a problem; several field studies have shown that these types of sensors do not always perform perfectly. Field tests conducted in this study and by other research teams showed that infrared sensors usually counted significantly fewer pedestrians than the actual number. Thus, the quality of the data from infrared sensors needs to be enhanced. This paper proposes a nonparametric statistical method to calibrate raw sensor data to achieve this goal. A bivariate bootstrap sampling procedure was used to obtain correction factors for new counts instead of the traditional regression-based approach. Two case studies were used to test the validation of the proposed calibration procedure. Test results showed that the proposed procedure could improve the quality of the sensor data by reducing the discrepancy between sensor counts and ground truth (true) data. The transferability of the calibration procedure was also verified through the case studies.

AB - With the advent of intelligent transportation systems in the past several decades, sensors are being extensively used to detect and count vehicle movements. The use of similar sensing technologies to detect pedestrian movements, however, is relatively new. Pedestrian counts are essential for decision making in pedestrian facility planning, signal timing, and pedestrian safety modeling. Conventional methods such as manual counting and videotaping can hardly satisfy the requirements of programs for the long-term collection of pedestrian data. Advances in sensing technologies have increased the ability to automate pedestrian data collection with the use of infrared sensors. However, the quality of the data from infrared sensors is still a problem; several field studies have shown that these types of sensors do not always perform perfectly. Field tests conducted in this study and by other research teams showed that infrared sensors usually counted significantly fewer pedestrians than the actual number. Thus, the quality of the data from infrared sensors needs to be enhanced. This paper proposes a nonparametric statistical method to calibrate raw sensor data to achieve this goal. A bivariate bootstrap sampling procedure was used to obtain correction factors for new counts instead of the traditional regression-based approach. Two case studies were used to test the validation of the proposed calibration procedure. Test results showed that the proposed procedure could improve the quality of the sensor data by reducing the discrepancy between sensor counts and ground truth (true) data. The transferability of the calibration procedure was also verified through the case studies.

UR - http://www.scopus.com/inward/record.url?scp=84863261678&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84863261678&partnerID=8YFLogxK

U2 - 10.3141/2264-02

DO - 10.3141/2264-02

M3 - Article

SP - 11

EP - 17

JO - Transportation Research Record

JF - Transportation Research Record

SN - 0361-1981

IS - 2264

ER -