Enhanced bone bonding to nanotextured implant surfaces at a short healing period: A biomechanical tensile testing in the rat femur

Paulo Coelho, Ricardo A. Zavanelli, Marcos B. Salles, Sinem Yeniyol, Nick Tovar, Ryo Jimbo

Research output: Contribution to journalArticle

Abstract

Purpose: To compare the bone bonding capabilities of 2 different surface treatments at an early healing period. Titanium alloy (Ti6Al4V) custom-made rectangular plates (1.4 × 2.4 × 4 mm) were either dual acid etched (Ti6Al4V- DAE) or DAE/nanotextured blasted (Ti6Al4V-NTB). Materials and Methods: Implants were placed in the distal femurs of 10 Wistar rats and were allowed to heal for 9 days. After euthanasia, the bone immediately proximal and distal to the implant was removed to test the bone bonding force with a universal testing machine. Ultrastructure of the bone/implant interface was assessed by scanning electron microscopy. Results: Ti6Al4V-NTB samples exhibited significantly greater bond strength than Ti6Al4V-DAE samples. Morphologically, the Ti6Al4V- NTB surfaces presented intimate interaction with bone, whereas little interaction between the Ti6Al4V-DAE surface and bone was observed. Conclusion: The results of this study indicated a significant increase in bone bonding for the DAE/nanotextured blasted surface, which is suggested to be the outcome of the nanotexturing.

Original languageEnglish (US)
Pages (from-to)322-327
Number of pages6
JournalImplant Dentistry
Volume25
Issue number3
DOIs
StatePublished - Jun 1 2016

Fingerprint

Femur
Bone and Bones
Euthanasia
Titanium
Electron Scanning Microscopy
titanium alloy (TiAl6V4)
Wistar Rats
Acids

Keywords

  • Biomechanical test
  • Bone bonding
  • Calcium phosphate
  • Implant surface
  • In vivo
  • Titanium alloy

ASJC Scopus subject areas

  • Oral Surgery

Cite this

Enhanced bone bonding to nanotextured implant surfaces at a short healing period : A biomechanical tensile testing in the rat femur. / Coelho, Paulo; Zavanelli, Ricardo A.; Salles, Marcos B.; Yeniyol, Sinem; Tovar, Nick; Jimbo, Ryo.

In: Implant Dentistry, Vol. 25, No. 3, 01.06.2016, p. 322-327.

Research output: Contribution to journalArticle

Coelho, Paulo ; Zavanelli, Ricardo A. ; Salles, Marcos B. ; Yeniyol, Sinem ; Tovar, Nick ; Jimbo, Ryo. / Enhanced bone bonding to nanotextured implant surfaces at a short healing period : A biomechanical tensile testing in the rat femur. In: Implant Dentistry. 2016 ; Vol. 25, No. 3. pp. 322-327.
@article{4ec5b1c1c6414b44bfffa645290d416c,
title = "Enhanced bone bonding to nanotextured implant surfaces at a short healing period: A biomechanical tensile testing in the rat femur",
abstract = "Purpose: To compare the bone bonding capabilities of 2 different surface treatments at an early healing period. Titanium alloy (Ti6Al4V) custom-made rectangular plates (1.4 × 2.4 × 4 mm) were either dual acid etched (Ti6Al4V- DAE) or DAE/nanotextured blasted (Ti6Al4V-NTB). Materials and Methods: Implants were placed in the distal femurs of 10 Wistar rats and were allowed to heal for 9 days. After euthanasia, the bone immediately proximal and distal to the implant was removed to test the bone bonding force with a universal testing machine. Ultrastructure of the bone/implant interface was assessed by scanning electron microscopy. Results: Ti6Al4V-NTB samples exhibited significantly greater bond strength than Ti6Al4V-DAE samples. Morphologically, the Ti6Al4V- NTB surfaces presented intimate interaction with bone, whereas little interaction between the Ti6Al4V-DAE surface and bone was observed. Conclusion: The results of this study indicated a significant increase in bone bonding for the DAE/nanotextured blasted surface, which is suggested to be the outcome of the nanotexturing.",
keywords = "Biomechanical test, Bone bonding, Calcium phosphate, Implant surface, In vivo, Titanium alloy",
author = "Paulo Coelho and Zavanelli, {Ricardo A.} and Salles, {Marcos B.} and Sinem Yeniyol and Nick Tovar and Ryo Jimbo",
year = "2016",
month = "6",
day = "1",
doi = "10.1097/ID.0000000000000436",
language = "English (US)",
volume = "25",
pages = "322--327",
journal = "Implant Dentistry",
issn = "1056-6163",
publisher = "Lippincott Williams and Wilkins",
number = "3",

}

TY - JOUR

T1 - Enhanced bone bonding to nanotextured implant surfaces at a short healing period

T2 - A biomechanical tensile testing in the rat femur

AU - Coelho, Paulo

AU - Zavanelli, Ricardo A.

AU - Salles, Marcos B.

AU - Yeniyol, Sinem

AU - Tovar, Nick

AU - Jimbo, Ryo

PY - 2016/6/1

Y1 - 2016/6/1

N2 - Purpose: To compare the bone bonding capabilities of 2 different surface treatments at an early healing period. Titanium alloy (Ti6Al4V) custom-made rectangular plates (1.4 × 2.4 × 4 mm) were either dual acid etched (Ti6Al4V- DAE) or DAE/nanotextured blasted (Ti6Al4V-NTB). Materials and Methods: Implants were placed in the distal femurs of 10 Wistar rats and were allowed to heal for 9 days. After euthanasia, the bone immediately proximal and distal to the implant was removed to test the bone bonding force with a universal testing machine. Ultrastructure of the bone/implant interface was assessed by scanning electron microscopy. Results: Ti6Al4V-NTB samples exhibited significantly greater bond strength than Ti6Al4V-DAE samples. Morphologically, the Ti6Al4V- NTB surfaces presented intimate interaction with bone, whereas little interaction between the Ti6Al4V-DAE surface and bone was observed. Conclusion: The results of this study indicated a significant increase in bone bonding for the DAE/nanotextured blasted surface, which is suggested to be the outcome of the nanotexturing.

AB - Purpose: To compare the bone bonding capabilities of 2 different surface treatments at an early healing period. Titanium alloy (Ti6Al4V) custom-made rectangular plates (1.4 × 2.4 × 4 mm) were either dual acid etched (Ti6Al4V- DAE) or DAE/nanotextured blasted (Ti6Al4V-NTB). Materials and Methods: Implants were placed in the distal femurs of 10 Wistar rats and were allowed to heal for 9 days. After euthanasia, the bone immediately proximal and distal to the implant was removed to test the bone bonding force with a universal testing machine. Ultrastructure of the bone/implant interface was assessed by scanning electron microscopy. Results: Ti6Al4V-NTB samples exhibited significantly greater bond strength than Ti6Al4V-DAE samples. Morphologically, the Ti6Al4V- NTB surfaces presented intimate interaction with bone, whereas little interaction between the Ti6Al4V-DAE surface and bone was observed. Conclusion: The results of this study indicated a significant increase in bone bonding for the DAE/nanotextured blasted surface, which is suggested to be the outcome of the nanotexturing.

KW - Biomechanical test

KW - Bone bonding

KW - Calcium phosphate

KW - Implant surface

KW - In vivo

KW - Titanium alloy

UR - http://www.scopus.com/inward/record.url?scp=84973444179&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84973444179&partnerID=8YFLogxK

U2 - 10.1097/ID.0000000000000436

DO - 10.1097/ID.0000000000000436

M3 - Article

C2 - 27213527

AN - SCOPUS:84973444179

VL - 25

SP - 322

EP - 327

JO - Implant Dentistry

JF - Implant Dentistry

SN - 1056-6163

IS - 3