Effects of barium concentration on oropharyngeal swallow timing measures

Shauna L. Stokely, Sonja Molfenter, Catriona M. Steele

Research output: Contribution to journalArticle

Abstract

Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

Original languageEnglish (US)
Pages (from-to)78-82
Number of pages5
JournalDysphagia
Volume29
Issue number1
DOIs
StatePublished - Feb 2014

Fingerprint

Barium
Deglutition
Upper Esophageal Sphincter
Analysis of Variance

Keywords

  • Barium concentration
  • Deglutition
  • Deglutition disorders
  • Dysphagia
  • Videofluoroscopy

ASJC Scopus subject areas

  • Otorhinolaryngology
  • Gastroenterology
  • Speech and Hearing
  • Medicine(all)

Cite this

Effects of barium concentration on oropharyngeal swallow timing measures. / Stokely, Shauna L.; Molfenter, Sonja; Steele, Catriona M.

In: Dysphagia, Vol. 29, No. 1, 02.2014, p. 78-82.

Research output: Contribution to journalArticle

Stokely, Shauna L. ; Molfenter, Sonja ; Steele, Catriona M. / Effects of barium concentration on oropharyngeal swallow timing measures. In: Dysphagia. 2014 ; Vol. 29, No. 1. pp. 78-82.
@article{3bba227ccf9640758271b60e506c46e5,
title = "Effects of barium concentration on oropharyngeal swallow timing measures",
abstract = "Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between {"}thin{"} (40 {\%} w/v concentration) and {"}ultrathin{"} (22 {\%} w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.",
keywords = "Barium concentration, Deglutition, Deglutition disorders, Dysphagia, Videofluoroscopy",
author = "Stokely, {Shauna L.} and Sonja Molfenter and Steele, {Catriona M.}",
year = "2014",
month = "2",
doi = "10.1007/s00455-013-9485-6",
language = "English (US)",
volume = "29",
pages = "78--82",
journal = "Dysphagia",
issn = "0179-051X",
publisher = "Springer New York",
number = "1",

}

TY - JOUR

T1 - Effects of barium concentration on oropharyngeal swallow timing measures

AU - Stokely, Shauna L.

AU - Molfenter, Sonja

AU - Steele, Catriona M.

PY - 2014/2

Y1 - 2014/2

N2 - Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

AB - Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

KW - Barium concentration

KW - Deglutition

KW - Deglutition disorders

KW - Dysphagia

KW - Videofluoroscopy

UR - http://www.scopus.com/inward/record.url?scp=84896736365&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84896736365&partnerID=8YFLogxK

U2 - 10.1007/s00455-013-9485-6

DO - 10.1007/s00455-013-9485-6

M3 - Article

C2 - 24045851

AN - SCOPUS:84896736365

VL - 29

SP - 78

EP - 82

JO - Dysphagia

JF - Dysphagia

SN - 0179-051X

IS - 1

ER -