Abstract

Sixty recently extracted intact anterior teeth were filled with Cavit G or Cavit. They were examined for dye penetration at room temperature and subjected to temperature change. Under the test conditions Cavit G and Cavit were resistant to penetration by aqueous methylene blue dye.

Original languageEnglish (US)
Pages (from-to)250-253
Number of pages4
JournalOral Surgery, Oral Medicine, Oral Pathology
Volume48
Issue number3
DOIs
StatePublished - 1979

Fingerprint

Coloring Agents
Temperature
Methylene Blue
Tooth
Cavit
Cavit G

ASJC Scopus subject areas

  • Pathology and Forensic Medicine
  • Dentistry(all)

Cite this

Effect of temperature change on the sealing properties of Cavit and Cavit G. / Oppenheimer, Steven; Rosenberg, Paul.

In: Oral Surgery, Oral Medicine, Oral Pathology, Vol. 48, No. 3, 1979, p. 250-253.

Research output: Contribution to journalArticle

@article{3253655453fe4bbd8f1db4b76e599a58,
title = "Effect of temperature change on the sealing properties of Cavit and Cavit G",
abstract = "Sixty recently extracted intact anterior teeth were filled with Cavit G or Cavit. They were examined for dye penetration at room temperature and subjected to temperature change. Under the test conditions Cavit G and Cavit were resistant to penetration by aqueous methylene blue dye.",
author = "Steven Oppenheimer and Paul Rosenberg",
year = "1979",
doi = "10.1016/0030-4220(79)90012-4",
language = "English (US)",
volume = "48",
pages = "250--253",
journal = "Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology",
issn = "2212-4403",
publisher = "Elsevier USA",
number = "3",

}

TY - JOUR

T1 - Effect of temperature change on the sealing properties of Cavit and Cavit G

AU - Oppenheimer, Steven

AU - Rosenberg, Paul

PY - 1979

Y1 - 1979

N2 - Sixty recently extracted intact anterior teeth were filled with Cavit G or Cavit. They were examined for dye penetration at room temperature and subjected to temperature change. Under the test conditions Cavit G and Cavit were resistant to penetration by aqueous methylene blue dye.

AB - Sixty recently extracted intact anterior teeth were filled with Cavit G or Cavit. They were examined for dye penetration at room temperature and subjected to temperature change. Under the test conditions Cavit G and Cavit were resistant to penetration by aqueous methylene blue dye.

UR - http://www.scopus.com/inward/record.url?scp=0018665740&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018665740&partnerID=8YFLogxK

U2 - 10.1016/0030-4220(79)90012-4

DO - 10.1016/0030-4220(79)90012-4

M3 - Article

C2 - 384326

AN - SCOPUS:0018665740

VL - 48

SP - 250

EP - 253

JO - Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology

JF - Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology

SN - 2212-4403

IS - 3

ER -