Effect of drilling dimension on implant placement torque and early osseointegration stages

An experimental study in dogs

Felipe E. Campos, Julio B. Gomes, Charles Marin, Hellen S. Teixeira, Marcelo Suzuki, Lukasz Witek, Darceny Zanetta-Barbosa, Paulo Coelho

Research output: Contribution to journalArticle

Abstract

Primary stability has been regarded as a key factor to ensure uneventful osseointegration of dental implants. Such stability is often achieved by placing implants in undersized drilled bone. The present study evaluated the effect of drilling dimensions in insertion torque and early implant osseointegration stages in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before death. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in diameter. The insertion torque was recorded for all samples. After death, the implants in bone were nondecalcified processed and morphologically and morphometrically (bone-to-implant contact and bone area fraction occupancy) evaluated. Statistical analyses were performed using the Kruskal-Wallis test followed by Dunn's post hoc test for multiple comparisons at the 95% level of significance. The insertion torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2-mm and 3.8-mm groups (P =.003). Despite a significant increase in the bone-to-implant contact over time in vivo for all groups (P =.007), no effect for the drilling dimension was observed. Additionally, no effect of the drilling dimension and time was observed for the bone area fraction occupancy parameter (P =.31). The initial healing pathways differed between implants placed in bone drilled to different dimensions. Although different degrees of torque were observed with different drilling dimensions and these resulted in different healing patterns, no differences in the histometrically evaluated parameters were observed.

Original languageEnglish (US)
JournalJournal of Oral and Maxillofacial Surgery
Volume70
Issue number1
DOIs
StatePublished - Jan 2012

Fingerprint

Osseointegration
Torque
Dogs
Bone and Bones
Dental Implants

ASJC Scopus subject areas

  • Oral Surgery
  • Otorhinolaryngology
  • Surgery

Cite this

Effect of drilling dimension on implant placement torque and early osseointegration stages : An experimental study in dogs. / Campos, Felipe E.; Gomes, Julio B.; Marin, Charles; Teixeira, Hellen S.; Suzuki, Marcelo; Witek, Lukasz; Zanetta-Barbosa, Darceny; Coelho, Paulo.

In: Journal of Oral and Maxillofacial Surgery, Vol. 70, No. 1, 01.2012.

Research output: Contribution to journalArticle

Campos, Felipe E. ; Gomes, Julio B. ; Marin, Charles ; Teixeira, Hellen S. ; Suzuki, Marcelo ; Witek, Lukasz ; Zanetta-Barbosa, Darceny ; Coelho, Paulo. / Effect of drilling dimension on implant placement torque and early osseointegration stages : An experimental study in dogs. In: Journal of Oral and Maxillofacial Surgery. 2012 ; Vol. 70, No. 1.
@article{3546cdf9dde54231964ffa5926d6f7ec,
title = "Effect of drilling dimension on implant placement torque and early osseointegration stages: An experimental study in dogs",
abstract = "Primary stability has been regarded as a key factor to ensure uneventful osseointegration of dental implants. Such stability is often achieved by placing implants in undersized drilled bone. The present study evaluated the effect of drilling dimensions in insertion torque and early implant osseointegration stages in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before death. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in diameter. The insertion torque was recorded for all samples. After death, the implants in bone were nondecalcified processed and morphologically and morphometrically (bone-to-implant contact and bone area fraction occupancy) evaluated. Statistical analyses were performed using the Kruskal-Wallis test followed by Dunn's post hoc test for multiple comparisons at the 95{\%} level of significance. The insertion torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2-mm and 3.8-mm groups (P =.003). Despite a significant increase in the bone-to-implant contact over time in vivo for all groups (P =.007), no effect for the drilling dimension was observed. Additionally, no effect of the drilling dimension and time was observed for the bone area fraction occupancy parameter (P =.31). The initial healing pathways differed between implants placed in bone drilled to different dimensions. Although different degrees of torque were observed with different drilling dimensions and these resulted in different healing patterns, no differences in the histometrically evaluated parameters were observed.",
author = "Campos, {Felipe E.} and Gomes, {Julio B.} and Charles Marin and Teixeira, {Hellen S.} and Marcelo Suzuki and Lukasz Witek and Darceny Zanetta-Barbosa and Paulo Coelho",
year = "2012",
month = "1",
doi = "10.1016/j.joms.2011.08.006",
language = "English (US)",
volume = "70",
journal = "Journal of Oral and Maxillofacial Surgery",
issn = "0278-2391",
publisher = "W.B. Saunders Ltd",
number = "1",

}

TY - JOUR

T1 - Effect of drilling dimension on implant placement torque and early osseointegration stages

T2 - An experimental study in dogs

AU - Campos, Felipe E.

AU - Gomes, Julio B.

AU - Marin, Charles

AU - Teixeira, Hellen S.

AU - Suzuki, Marcelo

AU - Witek, Lukasz

AU - Zanetta-Barbosa, Darceny

AU - Coelho, Paulo

PY - 2012/1

Y1 - 2012/1

N2 - Primary stability has been regarded as a key factor to ensure uneventful osseointegration of dental implants. Such stability is often achieved by placing implants in undersized drilled bone. The present study evaluated the effect of drilling dimensions in insertion torque and early implant osseointegration stages in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before death. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in diameter. The insertion torque was recorded for all samples. After death, the implants in bone were nondecalcified processed and morphologically and morphometrically (bone-to-implant contact and bone area fraction occupancy) evaluated. Statistical analyses were performed using the Kruskal-Wallis test followed by Dunn's post hoc test for multiple comparisons at the 95% level of significance. The insertion torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2-mm and 3.8-mm groups (P =.003). Despite a significant increase in the bone-to-implant contact over time in vivo for all groups (P =.007), no effect for the drilling dimension was observed. Additionally, no effect of the drilling dimension and time was observed for the bone area fraction occupancy parameter (P =.31). The initial healing pathways differed between implants placed in bone drilled to different dimensions. Although different degrees of torque were observed with different drilling dimensions and these resulted in different healing patterns, no differences in the histometrically evaluated parameters were observed.

AB - Primary stability has been regarded as a key factor to ensure uneventful osseointegration of dental implants. Such stability is often achieved by placing implants in undersized drilled bone. The present study evaluated the effect of drilling dimensions in insertion torque and early implant osseointegration stages in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before death. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in diameter. The insertion torque was recorded for all samples. After death, the implants in bone were nondecalcified processed and morphologically and morphometrically (bone-to-implant contact and bone area fraction occupancy) evaluated. Statistical analyses were performed using the Kruskal-Wallis test followed by Dunn's post hoc test for multiple comparisons at the 95% level of significance. The insertion torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2-mm and 3.8-mm groups (P =.003). Despite a significant increase in the bone-to-implant contact over time in vivo for all groups (P =.007), no effect for the drilling dimension was observed. Additionally, no effect of the drilling dimension and time was observed for the bone area fraction occupancy parameter (P =.31). The initial healing pathways differed between implants placed in bone drilled to different dimensions. Although different degrees of torque were observed with different drilling dimensions and these resulted in different healing patterns, no differences in the histometrically evaluated parameters were observed.

UR - http://www.scopus.com/inward/record.url?scp=84255189739&partnerID=8YFLogxK