Computer-assisted design of butterfly bileaflet valves for the mitral position

David M. Mcqueen, Charles Peskin

Research output: Contribution to journalArticle

Abstract

This paper describes the application of computer testing to a design study of butterfly bileaflet mitral prostheses having flat or curved leaflets. The curvature is in the plane normal to the pivot axes and is such that the convex sides of the leaflets face each other when the valve is open. The design parameters considered are the curvature of the leaflets and the location of the pivot points. In this study, stagnation is assessed by computing the smallest value (over the three openings of the valve) of the peak velocity, and hemodynamic performance is judged by a benefit/cost ratio: the net stroke volume divided by the mean transvalvular pressure difference. Unlike the case of a pivoting single-disc valve, the inclusion of a constraint on the maximum angle of opening of the leaflets is found to be essential for adequate, competent performance. Results are presented with both 85° and 90° constraints, since best performance is achieved with the opening-angle constraint in this range. Asymmetry of leaflet motion which is observed with flat leaflets in the mitral position is reduced with modest leaflet curvature. Leaflet curvature also ameliorates central orifice stagnation, which is observed with flat leaflets. Curvature of the valve produces the following improvements in comparison with the best flat valve when the opening-angle constraint is 85°: a 38 % increase in the minimum peak velocity and a 16% increase in the hemodynamic benefit/cost ratio. With a 90° constraint the corresponding improvements are 34% and 20% respectively.

Original languageEnglish (US)
Pages (from-to)139-148
Number of pages10
JournalScandinavian Cardiovascular Journal
Volume19
Issue number2
DOIs
StatePublished - 1985

Fingerprint

Computer-Aided Design
Butterflies
Mitral Valve
Cost-Benefit Analysis
Hemodynamics
Stroke Volume
Prostheses and Implants
Pressure

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Computer-assisted design of butterfly bileaflet valves for the mitral position. / Mcqueen, David M.; Peskin, Charles.

In: Scandinavian Cardiovascular Journal, Vol. 19, No. 2, 1985, p. 139-148.

Research output: Contribution to journalArticle

Mcqueen, David M. ; Peskin, Charles. / Computer-assisted design of butterfly bileaflet valves for the mitral position. In: Scandinavian Cardiovascular Journal. 1985 ; Vol. 19, No. 2. pp. 139-148.
@article{14ba6626b62a45628db249244c7d6e30,
title = "Computer-assisted design of butterfly bileaflet valves for the mitral position",
abstract = "This paper describes the application of computer testing to a design study of butterfly bileaflet mitral prostheses having flat or curved leaflets. The curvature is in the plane normal to the pivot axes and is such that the convex sides of the leaflets face each other when the valve is open. The design parameters considered are the curvature of the leaflets and the location of the pivot points. In this study, stagnation is assessed by computing the smallest value (over the three openings of the valve) of the peak velocity, and hemodynamic performance is judged by a benefit/cost ratio: the net stroke volume divided by the mean transvalvular pressure difference. Unlike the case of a pivoting single-disc valve, the inclusion of a constraint on the maximum angle of opening of the leaflets is found to be essential for adequate, competent performance. Results are presented with both 85° and 90° constraints, since best performance is achieved with the opening-angle constraint in this range. Asymmetry of leaflet motion which is observed with flat leaflets in the mitral position is reduced with modest leaflet curvature. Leaflet curvature also ameliorates central orifice stagnation, which is observed with flat leaflets. Curvature of the valve produces the following improvements in comparison with the best flat valve when the opening-angle constraint is 85°: a 38 {\%} increase in the minimum peak velocity and a 16{\%} increase in the hemodynamic benefit/cost ratio. With a 90° constraint the corresponding improvements are 34{\%} and 20{\%} respectively.",
author = "Mcqueen, {David M.} and Charles Peskin",
year = "1985",
doi = "10.3109/14017438509102709",
language = "English (US)",
volume = "19",
pages = "139--148",
journal = "Scandinavian Cardiovascular Journal",
issn = "1401-7431",
publisher = "Informa Healthcare",
number = "2",

}

TY - JOUR

T1 - Computer-assisted design of butterfly bileaflet valves for the mitral position

AU - Mcqueen, David M.

AU - Peskin, Charles

PY - 1985

Y1 - 1985

N2 - This paper describes the application of computer testing to a design study of butterfly bileaflet mitral prostheses having flat or curved leaflets. The curvature is in the plane normal to the pivot axes and is such that the convex sides of the leaflets face each other when the valve is open. The design parameters considered are the curvature of the leaflets and the location of the pivot points. In this study, stagnation is assessed by computing the smallest value (over the three openings of the valve) of the peak velocity, and hemodynamic performance is judged by a benefit/cost ratio: the net stroke volume divided by the mean transvalvular pressure difference. Unlike the case of a pivoting single-disc valve, the inclusion of a constraint on the maximum angle of opening of the leaflets is found to be essential for adequate, competent performance. Results are presented with both 85° and 90° constraints, since best performance is achieved with the opening-angle constraint in this range. Asymmetry of leaflet motion which is observed with flat leaflets in the mitral position is reduced with modest leaflet curvature. Leaflet curvature also ameliorates central orifice stagnation, which is observed with flat leaflets. Curvature of the valve produces the following improvements in comparison with the best flat valve when the opening-angle constraint is 85°: a 38 % increase in the minimum peak velocity and a 16% increase in the hemodynamic benefit/cost ratio. With a 90° constraint the corresponding improvements are 34% and 20% respectively.

AB - This paper describes the application of computer testing to a design study of butterfly bileaflet mitral prostheses having flat or curved leaflets. The curvature is in the plane normal to the pivot axes and is such that the convex sides of the leaflets face each other when the valve is open. The design parameters considered are the curvature of the leaflets and the location of the pivot points. In this study, stagnation is assessed by computing the smallest value (over the three openings of the valve) of the peak velocity, and hemodynamic performance is judged by a benefit/cost ratio: the net stroke volume divided by the mean transvalvular pressure difference. Unlike the case of a pivoting single-disc valve, the inclusion of a constraint on the maximum angle of opening of the leaflets is found to be essential for adequate, competent performance. Results are presented with both 85° and 90° constraints, since best performance is achieved with the opening-angle constraint in this range. Asymmetry of leaflet motion which is observed with flat leaflets in the mitral position is reduced with modest leaflet curvature. Leaflet curvature also ameliorates central orifice stagnation, which is observed with flat leaflets. Curvature of the valve produces the following improvements in comparison with the best flat valve when the opening-angle constraint is 85°: a 38 % increase in the minimum peak velocity and a 16% increase in the hemodynamic benefit/cost ratio. With a 90° constraint the corresponding improvements are 34% and 20% respectively.

UR - http://www.scopus.com/inward/record.url?scp=0021887985&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021887985&partnerID=8YFLogxK

U2 - 10.3109/14017438509102709

DO - 10.3109/14017438509102709

M3 - Article

VL - 19

SP - 139

EP - 148

JO - Scandinavian Cardiovascular Journal

JF - Scandinavian Cardiovascular Journal

SN - 1401-7431

IS - 2

ER -