Comparison of fatigue for three prefabricated threaded post systems

Frederick H. Kahn, Paul Rosenberg, Allan Schulman, Mitchell Pines

Research output: Contribution to journalArticle

Abstract

Post designs may have a direct effect on fracture resistance of endodontically treated teeth. This in vitro study compared the resistance of three prefabricated threaded post systems with lateral shearing forces. After endodontics were completed, prefabricated posts were inserted according to the manufacturer's instructions. A silver amalgam core was placed, and extracted human teeth were prepared to a standard size with a 1 mm gingival chamfer finished on sound dentin. A cast crown was fabricated and cemented, and the specimens were thermocycled. The test samples were secured to an Instron testing machine and loaded until failure. Fracture patterns were recorded, fractured surface areas were measured, and compressive stresses were calculated. However, there were no statistically significant differences among threaded posts in each test group.

Original languageEnglish (US)
Pages (from-to)148-153
Number of pages6
JournalJournal of Prosthetic Dentistry
Volume75
Issue number2
StatePublished - 1996

Fingerprint

Nonvital Tooth
Endodontics
Dentin
Crowns
Silver
Fatigue
Tooth
In Vitro Techniques

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Comparison of fatigue for three prefabricated threaded post systems. / Kahn, Frederick H.; Rosenberg, Paul; Schulman, Allan; Pines, Mitchell.

In: Journal of Prosthetic Dentistry, Vol. 75, No. 2, 1996, p. 148-153.

Research output: Contribution to journalArticle

Kahn, Frederick H. ; Rosenberg, Paul ; Schulman, Allan ; Pines, Mitchell. / Comparison of fatigue for three prefabricated threaded post systems. In: Journal of Prosthetic Dentistry. 1996 ; Vol. 75, No. 2. pp. 148-153.
@article{09441a13c2c6460582777787deacd57a,
title = "Comparison of fatigue for three prefabricated threaded post systems",
abstract = "Post designs may have a direct effect on fracture resistance of endodontically treated teeth. This in vitro study compared the resistance of three prefabricated threaded post systems with lateral shearing forces. After endodontics were completed, prefabricated posts were inserted according to the manufacturer's instructions. A silver amalgam core was placed, and extracted human teeth were prepared to a standard size with a 1 mm gingival chamfer finished on sound dentin. A cast crown was fabricated and cemented, and the specimens were thermocycled. The test samples were secured to an Instron testing machine and loaded until failure. Fracture patterns were recorded, fractured surface areas were measured, and compressive stresses were calculated. However, there were no statistically significant differences among threaded posts in each test group.",
author = "Kahn, {Frederick H.} and Paul Rosenberg and Allan Schulman and Mitchell Pines",
year = "1996",
language = "English (US)",
volume = "75",
pages = "148--153",
journal = "Journal of Prosthetic Dentistry",
issn = "0022-3913",
publisher = "Mosby Inc.",
number = "2",

}

TY - JOUR

T1 - Comparison of fatigue for three prefabricated threaded post systems

AU - Kahn, Frederick H.

AU - Rosenberg, Paul

AU - Schulman, Allan

AU - Pines, Mitchell

PY - 1996

Y1 - 1996

N2 - Post designs may have a direct effect on fracture resistance of endodontically treated teeth. This in vitro study compared the resistance of three prefabricated threaded post systems with lateral shearing forces. After endodontics were completed, prefabricated posts were inserted according to the manufacturer's instructions. A silver amalgam core was placed, and extracted human teeth were prepared to a standard size with a 1 mm gingival chamfer finished on sound dentin. A cast crown was fabricated and cemented, and the specimens were thermocycled. The test samples were secured to an Instron testing machine and loaded until failure. Fracture patterns were recorded, fractured surface areas were measured, and compressive stresses were calculated. However, there were no statistically significant differences among threaded posts in each test group.

AB - Post designs may have a direct effect on fracture resistance of endodontically treated teeth. This in vitro study compared the resistance of three prefabricated threaded post systems with lateral shearing forces. After endodontics were completed, prefabricated posts were inserted according to the manufacturer's instructions. A silver amalgam core was placed, and extracted human teeth were prepared to a standard size with a 1 mm gingival chamfer finished on sound dentin. A cast crown was fabricated and cemented, and the specimens were thermocycled. The test samples were secured to an Instron testing machine and loaded until failure. Fracture patterns were recorded, fractured surface areas were measured, and compressive stresses were calculated. However, there were no statistically significant differences among threaded posts in each test group.

UR - http://www.scopus.com/inward/record.url?scp=0030078021&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030078021&partnerID=8YFLogxK

M3 - Article

VL - 75

SP - 148

EP - 153

JO - Journal of Prosthetic Dentistry

JF - Journal of Prosthetic Dentistry

SN - 0022-3913

IS - 2

ER -