Calculation of pad cross-talk in a thin-gap multiwire detector with pad readout

A. I. Mincer, N. Z. Lupu, Y. Rozen, S. Tarem, D. Lazic, S. Dado, J. J. Goldberg, G. Bella, L. Levinson, G. Mikenberg

    Research output: Contribution to journalArticle

    Abstract

    Mechanisms responsible for cross-talk in a thin-gap multiwire chamber with pad readout are discussed. Using a simple capacitive coupling model, the cross-talk is calculated as a function of chamber geometry, capacitances and charge integration time. Calculation results are compared and found to be in reasonable agreement with measurements. Suggestions are given for reducing cross-talk in such a chamber.

    Original languageEnglish (US)
    Pages (from-to)41-50
    Number of pages10
    JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    Volume404
    Issue number1
    DOIs
    StatePublished - Feb 11 1998

    Fingerprint

    readout
    Capacitance
    chambers
    Detectors
    Geometry
    detectors
    suggestion
    capacitance
    geometry

    Keywords

    • Cross-talk
    • Thin-gap chamber

    ASJC Scopus subject areas

    • Instrumentation
    • Nuclear and High Energy Physics

    Cite this

    Calculation of pad cross-talk in a thin-gap multiwire detector with pad readout. / Mincer, A. I.; Lupu, N. Z.; Rozen, Y.; Tarem, S.; Lazic, D.; Dado, S.; Goldberg, J. J.; Bella, G.; Levinson, L.; Mikenberg, G.

    In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 404, No. 1, 11.02.1998, p. 41-50.

    Research output: Contribution to journalArticle

    Mincer, A. I. ; Lupu, N. Z. ; Rozen, Y. ; Tarem, S. ; Lazic, D. ; Dado, S. ; Goldberg, J. J. ; Bella, G. ; Levinson, L. ; Mikenberg, G. / Calculation of pad cross-talk in a thin-gap multiwire detector with pad readout. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1998 ; Vol. 404, No. 1. pp. 41-50.
    @article{1df2b30cdbb04853bbfa1f06bffa04e8,
    title = "Calculation of pad cross-talk in a thin-gap multiwire detector with pad readout",
    abstract = "Mechanisms responsible for cross-talk in a thin-gap multiwire chamber with pad readout are discussed. Using a simple capacitive coupling model, the cross-talk is calculated as a function of chamber geometry, capacitances and charge integration time. Calculation results are compared and found to be in reasonable agreement with measurements. Suggestions are given for reducing cross-talk in such a chamber.",
    keywords = "Cross-talk, Thin-gap chamber",
    author = "Mincer, {A. I.} and Lupu, {N. Z.} and Y. Rozen and S. Tarem and D. Lazic and S. Dado and Goldberg, {J. J.} and G. Bella and L. Levinson and G. Mikenberg",
    year = "1998",
    month = "2",
    day = "11",
    doi = "10.1016/S0168-9002(97)01069-3",
    language = "English (US)",
    volume = "404",
    pages = "41--50",
    journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
    issn = "0168-9002",
    publisher = "Elsevier",
    number = "1",

    }

    TY - JOUR

    T1 - Calculation of pad cross-talk in a thin-gap multiwire detector with pad readout

    AU - Mincer, A. I.

    AU - Lupu, N. Z.

    AU - Rozen, Y.

    AU - Tarem, S.

    AU - Lazic, D.

    AU - Dado, S.

    AU - Goldberg, J. J.

    AU - Bella, G.

    AU - Levinson, L.

    AU - Mikenberg, G.

    PY - 1998/2/11

    Y1 - 1998/2/11

    N2 - Mechanisms responsible for cross-talk in a thin-gap multiwire chamber with pad readout are discussed. Using a simple capacitive coupling model, the cross-talk is calculated as a function of chamber geometry, capacitances and charge integration time. Calculation results are compared and found to be in reasonable agreement with measurements. Suggestions are given for reducing cross-talk in such a chamber.

    AB - Mechanisms responsible for cross-talk in a thin-gap multiwire chamber with pad readout are discussed. Using a simple capacitive coupling model, the cross-talk is calculated as a function of chamber geometry, capacitances and charge integration time. Calculation results are compared and found to be in reasonable agreement with measurements. Suggestions are given for reducing cross-talk in such a chamber.

    KW - Cross-talk

    KW - Thin-gap chamber

    UR - http://www.scopus.com/inward/record.url?scp=0031999122&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0031999122&partnerID=8YFLogxK

    U2 - 10.1016/S0168-9002(97)01069-3

    DO - 10.1016/S0168-9002(97)01069-3

    M3 - Article

    VL - 404

    SP - 41

    EP - 50

    JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

    JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

    SN - 0168-9002

    IS - 1

    ER -