This study was to determine the shear bond strengths of Ni-Cr alloy to Ni-Cr alloy (Group I), Ni-Cr alloy to enamel (Group II), and Ni-Cr alloy to dentin (Group III) using Imperva Dual, DC Metabond, All-Bond, Geristore, and Panavia. All bonded specimens were thermocycled 2000 x (5 degrees C-55 degrees C) after 24 hours and subjected to shear bond testing on a Universal Instron Testing Machine. In all groups of the study, Imperva Dual and CB Metabond had significantly (p < .05) higher bond values than Panavia.

Original languageEnglish (US)
Pages (from-to)26-29
Number of pages4
JournalJournal of esthetic dentistry
Volume4 Suppl
StatePublished - 1992

Fingerprint

Resin Cements
Tooth
Shear Strength
Dentin
Dental Enamel
Adhesive cement

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Bonding Ni-Cr alloy to tooth structure with adhesive resin cements. / Penugonda, Bapanaiah; Scherer, W.; Cooper, Harmon; Kokoletsos, N.; Koifman, V.

In: Journal of esthetic dentistry, Vol. 4 Suppl, 1992, p. 26-29.

Research output: Contribution to journalArticle

@article{cb81c10e003146d39a6c85c6bbca6459,
title = "Bonding Ni-Cr alloy to tooth structure with adhesive resin cements.",
abstract = "This study was to determine the shear bond strengths of Ni-Cr alloy to Ni-Cr alloy (Group I), Ni-Cr alloy to enamel (Group II), and Ni-Cr alloy to dentin (Group III) using Imperva Dual, DC Metabond, All-Bond, Geristore, and Panavia. All bonded specimens were thermocycled 2000 x (5 degrees C-55 degrees C) after 24 hours and subjected to shear bond testing on a Universal Instron Testing Machine. In all groups of the study, Imperva Dual and CB Metabond had significantly (p < .05) higher bond values than Panavia.",
author = "Bapanaiah Penugonda and W. Scherer and Harmon Cooper and N. Kokoletsos and V. Koifman",
year = "1992",
language = "English (US)",
volume = "4 Suppl",
pages = "26--29",
journal = "Journal of Esthetic and Restorative Dentistry",
issn = "1496-4155",
publisher = "Wiley-Blackwell",

}

TY - JOUR

T1 - Bonding Ni-Cr alloy to tooth structure with adhesive resin cements.

AU - Penugonda, Bapanaiah

AU - Scherer, W.

AU - Cooper, Harmon

AU - Kokoletsos, N.

AU - Koifman, V.

PY - 1992

Y1 - 1992

N2 - This study was to determine the shear bond strengths of Ni-Cr alloy to Ni-Cr alloy (Group I), Ni-Cr alloy to enamel (Group II), and Ni-Cr alloy to dentin (Group III) using Imperva Dual, DC Metabond, All-Bond, Geristore, and Panavia. All bonded specimens were thermocycled 2000 x (5 degrees C-55 degrees C) after 24 hours and subjected to shear bond testing on a Universal Instron Testing Machine. In all groups of the study, Imperva Dual and CB Metabond had significantly (p < .05) higher bond values than Panavia.

AB - This study was to determine the shear bond strengths of Ni-Cr alloy to Ni-Cr alloy (Group I), Ni-Cr alloy to enamel (Group II), and Ni-Cr alloy to dentin (Group III) using Imperva Dual, DC Metabond, All-Bond, Geristore, and Panavia. All bonded specimens were thermocycled 2000 x (5 degrees C-55 degrees C) after 24 hours and subjected to shear bond testing on a Universal Instron Testing Machine. In all groups of the study, Imperva Dual and CB Metabond had significantly (p < .05) higher bond values than Panavia.

UR - http://www.scopus.com/inward/record.url?scp=0027023180&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027023180&partnerID=8YFLogxK

M3 - Article

VL - 4 Suppl

SP - 26

EP - 29

JO - Journal of Esthetic and Restorative Dentistry

JF - Journal of Esthetic and Restorative Dentistry

SN - 1496-4155

ER -