Biomechanical modeling of bone-needle interaction for haptic rendering in needle insertion simulation

J. S.K. Ong, C. K. Chui, Z. L. Wang, J. Zhang, Jeremy Teo, C. H. Yan, S. H. Ong, C. L. Teo, S. H. Teoh

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Medical simulators are increasingly being used for surgical training. For interactive surgical simulation involving haptic rendering, the force at the needle tip has to be computed very fast We are developing biomechanical models for bone needle insertion. The cortical bone can be regarded as a dense form of cancellous bone that can be modeled using a linear elastic material. The porosity of the bone determines the resistance felt as the user inserts the needle into the bone. The bar element method that represents each trabecular bone as a FE beam is most computationally efficient With 1000 FE elements, the computed force feedback were close to the insertion force measured during experiments. However, the extended bar element method may be the more appropriate choice for taking into consideration the trabecular distribution and hence, inhomogeneous of bone. The simulation studies on bone-needle interaction also showed that a diamond bevel needle may penetrate the bone with less force.

Original languageEnglish (US)
Title of host publication9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06
DOIs
StatePublished - Dec 1 2006
Event9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06 - Singapore, Singapore
Duration: Dec 5 2006Dec 8 2006

Other

Other9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06
CountrySingapore
CitySingapore
Period12/5/0612/8/06

Fingerprint

Needles
Bone
Diamonds
Porosity
Simulators
Feedback

Keywords

  • Bone
  • Haptics
  • Interactive modeling
  • Needle insertion

ASJC Scopus subject areas

  • Computer Science Applications
  • Computer Vision and Pattern Recognition
  • Control and Systems Engineering

Cite this

Ong, J. S. K., Chui, C. K., Wang, Z. L., Zhang, J., Teo, J., Yan, C. H., ... Teoh, S. H. (2006). Biomechanical modeling of bone-needle interaction for haptic rendering in needle insertion simulation. In 9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06 [4150406] https://doi.org/10.1109/ICARCV.2006.345477

Biomechanical modeling of bone-needle interaction for haptic rendering in needle insertion simulation. / Ong, J. S.K.; Chui, C. K.; Wang, Z. L.; Zhang, J.; Teo, Jeremy; Yan, C. H.; Ong, S. H.; Teo, C. L.; Teoh, S. H.

9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06. 2006. 4150406.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ong, JSK, Chui, CK, Wang, ZL, Zhang, J, Teo, J, Yan, CH, Ong, SH, Teo, CL & Teoh, SH 2006, Biomechanical modeling of bone-needle interaction for haptic rendering in needle insertion simulation. in 9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06., 4150406, 9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06, Singapore, Singapore, 12/5/06. https://doi.org/10.1109/ICARCV.2006.345477
Ong JSK, Chui CK, Wang ZL, Zhang J, Teo J, Yan CH et al. Biomechanical modeling of bone-needle interaction for haptic rendering in needle insertion simulation. In 9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06. 2006. 4150406 https://doi.org/10.1109/ICARCV.2006.345477
Ong, J. S.K. ; Chui, C. K. ; Wang, Z. L. ; Zhang, J. ; Teo, Jeremy ; Yan, C. H. ; Ong, S. H. ; Teo, C. L. ; Teoh, S. H. / Biomechanical modeling of bone-needle interaction for haptic rendering in needle insertion simulation. 9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06. 2006.
@inproceedings{8cc43ae0182e40a99d9294c359cfb699,
title = "Biomechanical modeling of bone-needle interaction for haptic rendering in needle insertion simulation",
abstract = "Medical simulators are increasingly being used for surgical training. For interactive surgical simulation involving haptic rendering, the force at the needle tip has to be computed very fast We are developing biomechanical models for bone needle insertion. The cortical bone can be regarded as a dense form of cancellous bone that can be modeled using a linear elastic material. The porosity of the bone determines the resistance felt as the user inserts the needle into the bone. The bar element method that represents each trabecular bone as a FE beam is most computationally efficient With 1000 FE elements, the computed force feedback were close to the insertion force measured during experiments. However, the extended bar element method may be the more appropriate choice for taking into consideration the trabecular distribution and hence, inhomogeneous of bone. The simulation studies on bone-needle interaction also showed that a diamond bevel needle may penetrate the bone with less force.",
keywords = "Bone, Haptics, Interactive modeling, Needle insertion",
author = "Ong, {J. S.K.} and Chui, {C. K.} and Wang, {Z. L.} and J. Zhang and Jeremy Teo and Yan, {C. H.} and Ong, {S. H.} and Teo, {C. L.} and Teoh, {S. H.}",
year = "2006",
month = "12",
day = "1",
doi = "10.1109/ICARCV.2006.345477",
language = "English (US)",
isbn = "1424403421",
booktitle = "9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06",

}

TY - GEN

T1 - Biomechanical modeling of bone-needle interaction for haptic rendering in needle insertion simulation

AU - Ong, J. S.K.

AU - Chui, C. K.

AU - Wang, Z. L.

AU - Zhang, J.

AU - Teo, Jeremy

AU - Yan, C. H.

AU - Ong, S. H.

AU - Teo, C. L.

AU - Teoh, S. H.

PY - 2006/12/1

Y1 - 2006/12/1

N2 - Medical simulators are increasingly being used for surgical training. For interactive surgical simulation involving haptic rendering, the force at the needle tip has to be computed very fast We are developing biomechanical models for bone needle insertion. The cortical bone can be regarded as a dense form of cancellous bone that can be modeled using a linear elastic material. The porosity of the bone determines the resistance felt as the user inserts the needle into the bone. The bar element method that represents each trabecular bone as a FE beam is most computationally efficient With 1000 FE elements, the computed force feedback were close to the insertion force measured during experiments. However, the extended bar element method may be the more appropriate choice for taking into consideration the trabecular distribution and hence, inhomogeneous of bone. The simulation studies on bone-needle interaction also showed that a diamond bevel needle may penetrate the bone with less force.

AB - Medical simulators are increasingly being used for surgical training. For interactive surgical simulation involving haptic rendering, the force at the needle tip has to be computed very fast We are developing biomechanical models for bone needle insertion. The cortical bone can be regarded as a dense form of cancellous bone that can be modeled using a linear elastic material. The porosity of the bone determines the resistance felt as the user inserts the needle into the bone. The bar element method that represents each trabecular bone as a FE beam is most computationally efficient With 1000 FE elements, the computed force feedback were close to the insertion force measured during experiments. However, the extended bar element method may be the more appropriate choice for taking into consideration the trabecular distribution and hence, inhomogeneous of bone. The simulation studies on bone-needle interaction also showed that a diamond bevel needle may penetrate the bone with less force.

KW - Bone

KW - Haptics

KW - Interactive modeling

KW - Needle insertion

UR - http://www.scopus.com/inward/record.url?scp=34547204576&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34547204576&partnerID=8YFLogxK

U2 - 10.1109/ICARCV.2006.345477

DO - 10.1109/ICARCV.2006.345477

M3 - Conference contribution

SN - 1424403421

SN - 9781424403424

BT - 9th International Conference on Control, Automation, Robotics and Vision, 2006, ICARCV '06

ER -