Biomechanical evaluation of an anatomically correct all-ceramic tooth-crown system configuration

Core layer multivariate analysis incorporating clinically relevant variables

Brian T. Rafferty, Estevam A. Bonfante, Malvin N. Janal, Nelson R F A Silva, Elizabeth D. Rekow, Van P. Thompson, Paulo Coelho

Research output: Contribution to journalArticle

Abstract

In a crown system, core fracture requires replacement of the restoration. Understanding maximum principal stress concentration in the veneered core of a tooth-crown system as a function of variations in clinically relevant parameters is crucial in the rational design of crown systems. This study evaluated the main and interacting effects of a set of clinical variables on the maximum principal stress (MPS) in the core of an anatomically correct veneer-core-cement-tooth model. A 3D CAD model of a mandibular first molar crown was generated; tooth preparation was modeled by reducing the proximal walls by 1.5 mm and the occlusal surface by 2.0 mm. A cemented veneered core crown was modeled on the preparation. This "crown system" permitted finite element model investigation of the main and interacting effects of proximal wall height reduction, core material, core thickness, cement modulus, cement thickness, and load position on the maximum stress distribution in a factorial design. Analysis of variance was used to identify the main and interacting influences on the level of MPS in the crown core. Statistical significance was set at p < 0.05. MPS levels varied as a function of two-way interactions between the following: core thickness and load position; cement thickness and load position; cement modulus and load position; cement thickness and core thickness; and cement thickness and cement modulus; and also three-way interactions among the load position, core material, and proximal wall height reduction, and among the core thickness, cement thickness, and cement modulus. MPS in the crown-tooth system is influenced by the design parameters and also by the interaction among them. Hence, while the geometry of molar crowns is complex, these analyses identify the factors that influence MPS and suggest levels that will minimize the core MPS in future studies of crown design.

Original languageEnglish (US)
JournalJournal of Biomechanical Engineering
Volume132
Issue number5
DOIs
StatePublished - May 2010

Fingerprint

Tooth Crown
Ceramics
Crowns
Cements
Multivariate Analysis
Tooth Preparation
Stress concentration
Veneers
Statistical Factor Analysis
Analysis of Variance
Tooth
Analysis of variance (ANOVA)
Restoration
Loads (forces)
Computer aided design

Keywords

  • All-ceramic crowns
  • Finite element analysis
  • Maximum principal stress
  • Multivariate analysis
  • Zirconia

ASJC Scopus subject areas

  • Biomedical Engineering
  • Physiology (medical)

Cite this

Biomechanical evaluation of an anatomically correct all-ceramic tooth-crown system configuration : Core layer multivariate analysis incorporating clinically relevant variables. / Rafferty, Brian T.; Bonfante, Estevam A.; Janal, Malvin N.; Silva, Nelson R F A; Rekow, Elizabeth D.; Thompson, Van P.; Coelho, Paulo.

In: Journal of Biomechanical Engineering, Vol. 132, No. 5, 05.2010.

Research output: Contribution to journalArticle

Rafferty, Brian T. ; Bonfante, Estevam A. ; Janal, Malvin N. ; Silva, Nelson R F A ; Rekow, Elizabeth D. ; Thompson, Van P. ; Coelho, Paulo. / Biomechanical evaluation of an anatomically correct all-ceramic tooth-crown system configuration : Core layer multivariate analysis incorporating clinically relevant variables. In: Journal of Biomechanical Engineering. 2010 ; Vol. 132, No. 5.
@article{f8cf0e467064493aaa23b757efe61ce5,
title = "Biomechanical evaluation of an anatomically correct all-ceramic tooth-crown system configuration: Core layer multivariate analysis incorporating clinically relevant variables",
abstract = "In a crown system, core fracture requires replacement of the restoration. Understanding maximum principal stress concentration in the veneered core of a tooth-crown system as a function of variations in clinically relevant parameters is crucial in the rational design of crown systems. This study evaluated the main and interacting effects of a set of clinical variables on the maximum principal stress (MPS) in the core of an anatomically correct veneer-core-cement-tooth model. A 3D CAD model of a mandibular first molar crown was generated; tooth preparation was modeled by reducing the proximal walls by 1.5 mm and the occlusal surface by 2.0 mm. A cemented veneered core crown was modeled on the preparation. This {"}crown system{"} permitted finite element model investigation of the main and interacting effects of proximal wall height reduction, core material, core thickness, cement modulus, cement thickness, and load position on the maximum stress distribution in a factorial design. Analysis of variance was used to identify the main and interacting influences on the level of MPS in the crown core. Statistical significance was set at p < 0.05. MPS levels varied as a function of two-way interactions between the following: core thickness and load position; cement thickness and load position; cement modulus and load position; cement thickness and core thickness; and cement thickness and cement modulus; and also three-way interactions among the load position, core material, and proximal wall height reduction, and among the core thickness, cement thickness, and cement modulus. MPS in the crown-tooth system is influenced by the design parameters and also by the interaction among them. Hence, while the geometry of molar crowns is complex, these analyses identify the factors that influence MPS and suggest levels that will minimize the core MPS in future studies of crown design.",
keywords = "All-ceramic crowns, Finite element analysis, Maximum principal stress, Multivariate analysis, Zirconia",
author = "Rafferty, {Brian T.} and Bonfante, {Estevam A.} and Janal, {Malvin N.} and Silva, {Nelson R F A} and Rekow, {Elizabeth D.} and Thompson, {Van P.} and Paulo Coelho",
year = "2010",
month = "5",
doi = "10.1115/1.4001046",
language = "English (US)",
volume = "132",
journal = "Journal of Biomechanical Engineering",
issn = "0148-0731",
publisher = "American Society of Mechanical Engineers(ASME)",
number = "5",

}

TY - JOUR

T1 - Biomechanical evaluation of an anatomically correct all-ceramic tooth-crown system configuration

T2 - Core layer multivariate analysis incorporating clinically relevant variables

AU - Rafferty, Brian T.

AU - Bonfante, Estevam A.

AU - Janal, Malvin N.

AU - Silva, Nelson R F A

AU - Rekow, Elizabeth D.

AU - Thompson, Van P.

AU - Coelho, Paulo

PY - 2010/5

Y1 - 2010/5

N2 - In a crown system, core fracture requires replacement of the restoration. Understanding maximum principal stress concentration in the veneered core of a tooth-crown system as a function of variations in clinically relevant parameters is crucial in the rational design of crown systems. This study evaluated the main and interacting effects of a set of clinical variables on the maximum principal stress (MPS) in the core of an anatomically correct veneer-core-cement-tooth model. A 3D CAD model of a mandibular first molar crown was generated; tooth preparation was modeled by reducing the proximal walls by 1.5 mm and the occlusal surface by 2.0 mm. A cemented veneered core crown was modeled on the preparation. This "crown system" permitted finite element model investigation of the main and interacting effects of proximal wall height reduction, core material, core thickness, cement modulus, cement thickness, and load position on the maximum stress distribution in a factorial design. Analysis of variance was used to identify the main and interacting influences on the level of MPS in the crown core. Statistical significance was set at p < 0.05. MPS levels varied as a function of two-way interactions between the following: core thickness and load position; cement thickness and load position; cement modulus and load position; cement thickness and core thickness; and cement thickness and cement modulus; and also three-way interactions among the load position, core material, and proximal wall height reduction, and among the core thickness, cement thickness, and cement modulus. MPS in the crown-tooth system is influenced by the design parameters and also by the interaction among them. Hence, while the geometry of molar crowns is complex, these analyses identify the factors that influence MPS and suggest levels that will minimize the core MPS in future studies of crown design.

AB - In a crown system, core fracture requires replacement of the restoration. Understanding maximum principal stress concentration in the veneered core of a tooth-crown system as a function of variations in clinically relevant parameters is crucial in the rational design of crown systems. This study evaluated the main and interacting effects of a set of clinical variables on the maximum principal stress (MPS) in the core of an anatomically correct veneer-core-cement-tooth model. A 3D CAD model of a mandibular first molar crown was generated; tooth preparation was modeled by reducing the proximal walls by 1.5 mm and the occlusal surface by 2.0 mm. A cemented veneered core crown was modeled on the preparation. This "crown system" permitted finite element model investigation of the main and interacting effects of proximal wall height reduction, core material, core thickness, cement modulus, cement thickness, and load position on the maximum stress distribution in a factorial design. Analysis of variance was used to identify the main and interacting influences on the level of MPS in the crown core. Statistical significance was set at p < 0.05. MPS levels varied as a function of two-way interactions between the following: core thickness and load position; cement thickness and load position; cement modulus and load position; cement thickness and core thickness; and cement thickness and cement modulus; and also three-way interactions among the load position, core material, and proximal wall height reduction, and among the core thickness, cement thickness, and cement modulus. MPS in the crown-tooth system is influenced by the design parameters and also by the interaction among them. Hence, while the geometry of molar crowns is complex, these analyses identify the factors that influence MPS and suggest levels that will minimize the core MPS in future studies of crown design.

KW - All-ceramic crowns

KW - Finite element analysis

KW - Maximum principal stress

KW - Multivariate analysis

KW - Zirconia

UR - http://www.scopus.com/inward/record.url?scp=77955118039&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77955118039&partnerID=8YFLogxK

U2 - 10.1115/1.4001046

DO - 10.1115/1.4001046

M3 - Article

VL - 132

JO - Journal of Biomechanical Engineering

JF - Journal of Biomechanical Engineering

SN - 0148-0731

IS - 5

ER -