Axial load effects on flush end-plate moment connections

Alireza Goudarzi, Mehdi Ghassemieh, Nader Fanaie, Debra Laefer, Mahmoud Baei

Research output: Contribution to journalArticle

Abstract

This numerical study focuses on the behavior of flush, end-plate, moment connections subjected to combined bending moment and axial force. Beams within frames are subjected to lateral loads (e.g. earthquake and wind) in the form of axial forces and bending moments. Thus, both must be considered in seismic design. In pitched-roof portal frames, sway frames or frames with incomplete floors, the level of axial forces in such joints may be significant. To partially fulfill this dual requirement, two distinctive flush, end-plate, moment connections were investigated: one to exhibit thick, connection-plate behavior and the other to exhibit thin, connection-plate behavior. The magnitude of the imposed axial force changes the failure mode. When subjected to reversed cyclic loading, distinctive behaviors between the two end-plate connection types were observed. During cyclic loading, in the axial compressive force phase, there was an increase in the ultimate bending moment, yielding bending moment, initial stiffness, and dissipated energy. Reductions occurred in all of these elements during the tensile axial force phase. As expected, the thin end-plate had notably higher ductility than the thick end-plate connection. In both connections, the maximum moment capacity under compressive axial force nearly equaled 30% of the beam’s section yield stress.

Original languageEnglish (US)
Article number1500042
Pages (from-to)199-210
Number of pages12
JournalProceedings of the Institution of Civil Engineers: Structures and Buildings
Volume170
Issue number3
DOIs
StatePublished - Mar 1 2017

Fingerprint

Axial loads
Bending moments
Seismic design
Roofs
Failure modes
Yield stress
Ductility
Earthquakes
Stiffness

Keywords

  • Beams & girders
  • Buildings
  • Steel structures
  • Structures & design

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction

Cite this

Axial load effects on flush end-plate moment connections. / Goudarzi, Alireza; Ghassemieh, Mehdi; Fanaie, Nader; Laefer, Debra; Baei, Mahmoud.

In: Proceedings of the Institution of Civil Engineers: Structures and Buildings, Vol. 170, No. 3, 1500042, 01.03.2017, p. 199-210.

Research output: Contribution to journalArticle

Goudarzi, Alireza ; Ghassemieh, Mehdi ; Fanaie, Nader ; Laefer, Debra ; Baei, Mahmoud. / Axial load effects on flush end-plate moment connections. In: Proceedings of the Institution of Civil Engineers: Structures and Buildings. 2017 ; Vol. 170, No. 3. pp. 199-210.
@article{693eeeffaeda43ca95a97f8e93eec882,
title = "Axial load effects on flush end-plate moment connections",
abstract = "This numerical study focuses on the behavior of flush, end-plate, moment connections subjected to combined bending moment and axial force. Beams within frames are subjected to lateral loads (e.g. earthquake and wind) in the form of axial forces and bending moments. Thus, both must be considered in seismic design. In pitched-roof portal frames, sway frames or frames with incomplete floors, the level of axial forces in such joints may be significant. To partially fulfill this dual requirement, two distinctive flush, end-plate, moment connections were investigated: one to exhibit thick, connection-plate behavior and the other to exhibit thin, connection-plate behavior. The magnitude of the imposed axial force changes the failure mode. When subjected to reversed cyclic loading, distinctive behaviors between the two end-plate connection types were observed. During cyclic loading, in the axial compressive force phase, there was an increase in the ultimate bending moment, yielding bending moment, initial stiffness, and dissipated energy. Reductions occurred in all of these elements during the tensile axial force phase. As expected, the thin end-plate had notably higher ductility than the thick end-plate connection. In both connections, the maximum moment capacity under compressive axial force nearly equaled 30{\%} of the beam’s section yield stress.",
keywords = "Beams & girders, Buildings, Steel structures, Structures & design",
author = "Alireza Goudarzi and Mehdi Ghassemieh and Nader Fanaie and Debra Laefer and Mahmoud Baei",
year = "2017",
month = "3",
day = "1",
doi = "10.1680/jstbu.15.00042",
language = "English (US)",
volume = "170",
pages = "199--210",
journal = "Proceedings of the Institution of Civil Engineers: Structures and Buildings",
issn = "0965-0911",
publisher = "ICE Publishing Ltd.",
number = "3",

}

TY - JOUR

T1 - Axial load effects on flush end-plate moment connections

AU - Goudarzi, Alireza

AU - Ghassemieh, Mehdi

AU - Fanaie, Nader

AU - Laefer, Debra

AU - Baei, Mahmoud

PY - 2017/3/1

Y1 - 2017/3/1

N2 - This numerical study focuses on the behavior of flush, end-plate, moment connections subjected to combined bending moment and axial force. Beams within frames are subjected to lateral loads (e.g. earthquake and wind) in the form of axial forces and bending moments. Thus, both must be considered in seismic design. In pitched-roof portal frames, sway frames or frames with incomplete floors, the level of axial forces in such joints may be significant. To partially fulfill this dual requirement, two distinctive flush, end-plate, moment connections were investigated: one to exhibit thick, connection-plate behavior and the other to exhibit thin, connection-plate behavior. The magnitude of the imposed axial force changes the failure mode. When subjected to reversed cyclic loading, distinctive behaviors between the two end-plate connection types were observed. During cyclic loading, in the axial compressive force phase, there was an increase in the ultimate bending moment, yielding bending moment, initial stiffness, and dissipated energy. Reductions occurred in all of these elements during the tensile axial force phase. As expected, the thin end-plate had notably higher ductility than the thick end-plate connection. In both connections, the maximum moment capacity under compressive axial force nearly equaled 30% of the beam’s section yield stress.

AB - This numerical study focuses on the behavior of flush, end-plate, moment connections subjected to combined bending moment and axial force. Beams within frames are subjected to lateral loads (e.g. earthquake and wind) in the form of axial forces and bending moments. Thus, both must be considered in seismic design. In pitched-roof portal frames, sway frames or frames with incomplete floors, the level of axial forces in such joints may be significant. To partially fulfill this dual requirement, two distinctive flush, end-plate, moment connections were investigated: one to exhibit thick, connection-plate behavior and the other to exhibit thin, connection-plate behavior. The magnitude of the imposed axial force changes the failure mode. When subjected to reversed cyclic loading, distinctive behaviors between the two end-plate connection types were observed. During cyclic loading, in the axial compressive force phase, there was an increase in the ultimate bending moment, yielding bending moment, initial stiffness, and dissipated energy. Reductions occurred in all of these elements during the tensile axial force phase. As expected, the thin end-plate had notably higher ductility than the thick end-plate connection. In both connections, the maximum moment capacity under compressive axial force nearly equaled 30% of the beam’s section yield stress.

KW - Beams & girders

KW - Buildings

KW - Steel structures

KW - Structures & design

UR - http://www.scopus.com/inward/record.url?scp=85012016498&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85012016498&partnerID=8YFLogxK

U2 - 10.1680/jstbu.15.00042

DO - 10.1680/jstbu.15.00042

M3 - Article

VL - 170

SP - 199

EP - 210

JO - Proceedings of the Institution of Civil Engineers: Structures and Buildings

JF - Proceedings of the Institution of Civil Engineers: Structures and Buildings

SN - 0965-0911

IS - 3

M1 - 1500042

ER -