Acceleration-based joint stability parameters for total knee arthroplasty that correspond with patient-reported instability

Dustyn Roberts, Humera Khan, Joo Hyun Kim, James Slover, Peter S. Walker

Research output: Contribution to journalArticle

Abstract

There is no universally accepted definition of human joint stability, particularly in nonperiodic general activities of daily living. Instability has proven to be a difficult parameter to define and quantify, since both spatial and temporal measures need to be considered to fully characterize joint stability. In this preliminary study, acceleration-based parameters were proposed to characterize the joint stability. Several time-statistical parameters of acceleration and jerk were defined as potential stability measures, since anomalous acceleration or jerk could be a symptom of poor control or stability. An inertial measurement unit attached at the level of the tibial tubercle of controls and patients following total knee arthroplasty was used to determine linear acceleration of the knee joint during several activities of daily living. The resulting accelerations and jerks were compared with patient-reported instability as determined through a standard questionnaire. Several parameters based on accelerations and jerks in the anterior/posterior direction during the step-up/step-down activity were significantly different between patients and controls and correlated with patient reports of instability in that activity. The range of the positive to negative peak acceleration and infinity norm of acceleration, in the anterior/posterior direction during the step-up/step-down activity, proved to be the best indicators of instability. As time derivatives of displacement, these acceleration-based parameters represent spatial and temporal information and are an important step forward in developing a definition and objective quantification of human joint stability that can complement the subjective patient report.

Original languageEnglish (US)
Pages (from-to)1104-1113
Number of pages10
JournalProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Volume227
Issue number10
DOIs
StatePublished - Oct 2013

Fingerprint

Arthroplasty
Knee Replacement Arthroplasties
Joints
Activities of Daily Living
Units of measurement
Knee Joint
Derivatives

Keywords

  • Acceleration
  • Activities of daily living
  • Inertial measurement unit
  • Jerk
  • Joint stability
  • Patient report
  • Stability
  • Total knee arthroplasty
  • Total knee replacement

ASJC Scopus subject areas

  • Mechanical Engineering
  • Medicine(all)

Cite this

Acceleration-based joint stability parameters for total knee arthroplasty that correspond with patient-reported instability. / Roberts, Dustyn; Khan, Humera; Kim, Joo Hyun; Slover, James; Walker, Peter S.

In: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, Vol. 227, No. 10, 10.2013, p. 1104-1113.

Research output: Contribution to journalArticle

@article{25d0607747cb435db07a8dcd91101ce2,
title = "Acceleration-based joint stability parameters for total knee arthroplasty that correspond with patient-reported instability",
abstract = "There is no universally accepted definition of human joint stability, particularly in nonperiodic general activities of daily living. Instability has proven to be a difficult parameter to define and quantify, since both spatial and temporal measures need to be considered to fully characterize joint stability. In this preliminary study, acceleration-based parameters were proposed to characterize the joint stability. Several time-statistical parameters of acceleration and jerk were defined as potential stability measures, since anomalous acceleration or jerk could be a symptom of poor control or stability. An inertial measurement unit attached at the level of the tibial tubercle of controls and patients following total knee arthroplasty was used to determine linear acceleration of the knee joint during several activities of daily living. The resulting accelerations and jerks were compared with patient-reported instability as determined through a standard questionnaire. Several parameters based on accelerations and jerks in the anterior/posterior direction during the step-up/step-down activity were significantly different between patients and controls and correlated with patient reports of instability in that activity. The range of the positive to negative peak acceleration and infinity norm of acceleration, in the anterior/posterior direction during the step-up/step-down activity, proved to be the best indicators of instability. As time derivatives of displacement, these acceleration-based parameters represent spatial and temporal information and are an important step forward in developing a definition and objective quantification of human joint stability that can complement the subjective patient report.",
keywords = "Acceleration, Activities of daily living, Inertial measurement unit, Jerk, Joint stability, Patient report, Stability, Total knee arthroplasty, Total knee replacement",
author = "Dustyn Roberts and Humera Khan and Kim, {Joo Hyun} and James Slover and Walker, {Peter S.}",
year = "2013",
month = "10",
doi = "10.1177/0954411913493724",
language = "English (US)",
volume = "227",
pages = "1104--1113",
journal = "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine",
issn = "0954-4119",
publisher = "SAGE Publications Ltd",
number = "10",

}

TY - JOUR

T1 - Acceleration-based joint stability parameters for total knee arthroplasty that correspond with patient-reported instability

AU - Roberts, Dustyn

AU - Khan, Humera

AU - Kim, Joo Hyun

AU - Slover, James

AU - Walker, Peter S.

PY - 2013/10

Y1 - 2013/10

N2 - There is no universally accepted definition of human joint stability, particularly in nonperiodic general activities of daily living. Instability has proven to be a difficult parameter to define and quantify, since both spatial and temporal measures need to be considered to fully characterize joint stability. In this preliminary study, acceleration-based parameters were proposed to characterize the joint stability. Several time-statistical parameters of acceleration and jerk were defined as potential stability measures, since anomalous acceleration or jerk could be a symptom of poor control or stability. An inertial measurement unit attached at the level of the tibial tubercle of controls and patients following total knee arthroplasty was used to determine linear acceleration of the knee joint during several activities of daily living. The resulting accelerations and jerks were compared with patient-reported instability as determined through a standard questionnaire. Several parameters based on accelerations and jerks in the anterior/posterior direction during the step-up/step-down activity were significantly different between patients and controls and correlated with patient reports of instability in that activity. The range of the positive to negative peak acceleration and infinity norm of acceleration, in the anterior/posterior direction during the step-up/step-down activity, proved to be the best indicators of instability. As time derivatives of displacement, these acceleration-based parameters represent spatial and temporal information and are an important step forward in developing a definition and objective quantification of human joint stability that can complement the subjective patient report.

AB - There is no universally accepted definition of human joint stability, particularly in nonperiodic general activities of daily living. Instability has proven to be a difficult parameter to define and quantify, since both spatial and temporal measures need to be considered to fully characterize joint stability. In this preliminary study, acceleration-based parameters were proposed to characterize the joint stability. Several time-statistical parameters of acceleration and jerk were defined as potential stability measures, since anomalous acceleration or jerk could be a symptom of poor control or stability. An inertial measurement unit attached at the level of the tibial tubercle of controls and patients following total knee arthroplasty was used to determine linear acceleration of the knee joint during several activities of daily living. The resulting accelerations and jerks were compared with patient-reported instability as determined through a standard questionnaire. Several parameters based on accelerations and jerks in the anterior/posterior direction during the step-up/step-down activity were significantly different between patients and controls and correlated with patient reports of instability in that activity. The range of the positive to negative peak acceleration and infinity norm of acceleration, in the anterior/posterior direction during the step-up/step-down activity, proved to be the best indicators of instability. As time derivatives of displacement, these acceleration-based parameters represent spatial and temporal information and are an important step forward in developing a definition and objective quantification of human joint stability that can complement the subjective patient report.

KW - Acceleration

KW - Activities of daily living

KW - Inertial measurement unit

KW - Jerk

KW - Joint stability

KW - Patient report

KW - Stability

KW - Total knee arthroplasty

KW - Total knee replacement

UR - http://www.scopus.com/inward/record.url?scp=84890544349&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890544349&partnerID=8YFLogxK

U2 - 10.1177/0954411913493724

DO - 10.1177/0954411913493724

M3 - Article

C2 - 23886970

AN - SCOPUS:84890544349

VL - 227

SP - 1104

EP - 1113

JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

SN - 0954-4119

IS - 10

ER -